Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chien, Chih-Liang | en_US |
dc.contributor.author | Iswara, Aditya Prana | en_US |
dc.contributor.author | Liou, Yi-Ling | en_US |
dc.contributor.author | Wang, Bing-Tsai | en_US |
dc.contributor.author | Chang, Jui-Chiao | en_US |
dc.contributor.author | Hung, Yi-Hung | en_US |
dc.contributor.author | Tsai, Chuen-Jinn | en_US |
dc.date.accessioned | 2015-12-02T02:59:35Z | - |
dc.date.available | 2015-12-02T02:59:35Z | - |
dc.date.issued | 2015-11-05 | en_US |
dc.identifier.issn | 1383-5866 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.seppur.2015.09.033 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/128375 | - |
dc.description.abstract | This study used a parallel-plate wet denuder coupled with an ion chromatograph (PPWD-IC) to monitor soluble gas pollutants in the exhaust stack and investigate the removal efficiency of packed towers. Gas pollutant concentrations measured by the PPWD-IC system were first validated with those obtained by a manual porous metal denuder sampler (PDS) as the reference sampler. The measured concentrations of the PPWD-IC system are in good agreement with those of the PDS with the coefficient of determination (R-2) greater than 0.93. The PPWD-IC system was then used to determine the removal efficiency of packed towers in high-tech factories. Results show that the PPWD-IC system is able to monitor multiple high-concentration gas pollutants semi-continuously, such as HF, HCl, HNO2, HNO3, CH3COOH, and NH3, in the exhaust stack with a temporal resolution of 20 min. The PPWD-IC system was employed to test the gas removal efficiency of a new honeycomb wet scrubber in an optoelectronic factory. The removal efficiency of the wet scrubber equipped with the honeycomb module at the liquid-to-gas ratio of 18.5 L/m(3) is shown to be close to 100% for HF (112.4-448.4 ppbv) and CH3COOH (696.3-6537.0 ppbv) and 99% for HCI (3394,9-10794.5 ppbv), respectively. (C) 2015 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Parallel-plate wet denuder | en_US |
dc.subject | Soluble gas pollutants | en_US |
dc.subject | Packed tower | en_US |
dc.subject | Removal efficiency | en_US |
dc.subject | Honeycomb wet scrubber | en_US |
dc.title | A real-time monitoring system for soluble gas pollutants and it's application for determining the control efficiency of packed towers | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.seppur.2015.09.033 | en_US |
dc.identifier.journal | SEPARATION AND PURIFICATION TECHNOLOGY | en_US |
dc.citation.volume | 154 | en_US |
dc.citation.spage | 137 | en_US |
dc.citation.epage | 148 | en_US |
dc.contributor.department | 環境工程研究所 | zh_TW |
dc.contributor.department | Institute of Environmental Engineering | en_US |
dc.identifier.wosnumber | WOS:000364245500018 | en_US |
dc.citation.woscount | 0 | en_US |
Appears in Collections: | Articles |