dc.description.abstract | Heat transfer and associated frictional pressure drop in the condensing flow of the ozone friendly refrigerant R-410A in a vertical plate heat exchanger (PHE) are investigated experimentally in the present study. In the experiment two vertical counter flow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60 degrees. Downflow of the condensing refrigerant R-410A in one channel releases heat to the upflow of cold water in the other channel. The effects of the refrigerant mass flux, imposed heat flux, system pressure (saturated temperature) and mean vapor quality of R-410A on the measured data are explored in detail. The results indicate that the R-410A condensation heat transfer coefficient and associated frictional pressure drop in the PHE increase almost linearly with the mean vapor quality, but the system pressure only exhibits rather slight effects. Furthermore, increases in the refrigerant mass flux and imposed heat flux result in better condensation heat transfer accompanying with a larger frictional pressure drop. Besides, the imposed heat flux exhibits stronger effects on the heat transfer coefficient and pressure drop than the refrigerant mass flux especially at low refrigerant vapor quality. The friction factor is found to be strongly influenced by the refrigerant mass flux and vapor quality, but is almost independent of the imposed heat flux and saturated pressure. Finally, an empirical correlation for the R-410A condensation heat transfer coefficient in the PHE is proposed. In addition, results for the friction factor are correlated against the Boiling number and equivalent Reynolds number of the two-phase condensing flow. (c) 2005 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.title | Condensation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.ijheatmasstransfer.2005.07.023 | en_US |
dc.identifier.journal | INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER | en_US |
dc.citation.volume | 48 | en_US |
dc.citation.issue | 25-26 | en_US |
dc.citation.spage | 5205 | en_US |
dc.citation.epage | 5220 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000233676800010 | - |
dc.citation.woscount | 34 | - |
顯示於類別: | 期刊論文 |