Full metadata record
DC FieldValueLanguage
dc.contributor.authorPrabhu, Gurpur Rakesh D.en_US
dc.contributor.authorUrban, Pawel L.en_US
dc.date.accessioned2017-04-21T06:56:29Z-
dc.date.available2017-04-21T06:56:29Z-
dc.date.issued2016-12-06en_US
dc.identifier.issn0003-2700en_US
dc.identifier.urihttp://dx.doi.org/10.1021/acs.analchem.6b0634en_US
dc.identifier.urihttp://hdl.handle.net/11536/132747-
dc.description.abstractGasometric assays involve measurements of the amounts of gases that are released during physical or chemical processes. The available instrumentation for gasometric analysis is generally difficult to use and requires large sample volumes. In some cases, toxic materials (mercury) are involved in the analysis process. Here, we propose a microscale gasometric assay using silicone oil as matrix. Microliter-volume (similar to 2.5 mu L) aqueous droplets, containing sample and reagent and/or catalyst, are introduced to the oil matrix and merged. Nanoliters of gaseous products are released to the surrounding oil matrix forming tiny spherical bubbles. Due to the huge differences between refractive indices of the released gas and the surrounding liquids (aqueous assay solution, oil), the gas bubbles are clearly visible from the top, when the assay reservoir is illuminated from the bottom with light emitting diodes. The released gas bubbles are documented by recording videos of the assay reservoir. Individual frames within these videos are then analyzed by a graphical software to obtain diameters of every gas bubble at each time point. Following a fixed period of time (typically, 5-90 s) after the sample/reagent droplet merger, the volume of the released gas scales with the amount of the substrate (analyte) present in the sample droplet. For example, hydrogen peroxide can be decomposed to oxygen by 0.44 U catalase enzyme and semiquantified in the range up to similar to 1.0 mu mol. Glutathione can be detected in a two-step procedure ((1) oxidation of glutathione by hydrogen peroxide; (2) decomposition of the hydrogen peroxide residue by catalase).en_US
dc.language.isoen_USen_US
dc.titleIn-Oleo Microgasometry of Nanoliter-Scale Gas Volumes with Image-Based Detectionen_US
dc.identifier.doi10.1021/acs.analchem.6b0634en_US
dc.identifier.journalANALYTICAL CHEMISTRYen_US
dc.citation.volume88en_US
dc.citation.issue23en_US
dc.citation.spage11368en_US
dc.citation.epage11372en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.identifier.wosnumberWOS:000389556900020en_US
Appears in Collections:Articles