完整後設資料紀錄
DC 欄位語言
dc.contributor.authorTu, Lung-Chenen_US
dc.contributor.authorWu, Ming-Chyaen_US
dc.contributor.authorChu, Hsueh-Liangen_US
dc.contributor.authorChiang, Yi-Pinen_US
dc.contributor.authorKuo, Chih-Linen_US
dc.contributor.authorLi, Hsing-Yuanen_US
dc.contributor.authorChang, Chia-Chingen_US
dc.date.accessioned2017-04-21T06:55:15Z-
dc.date.available2017-04-21T06:55:15Z-
dc.date.issued2016-06en_US
dc.identifier.issn1050-6411en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.jelekin.2016.02.009en_US
dc.identifier.urihttp://hdl.handle.net/11536/133749-
dc.description.abstractUpper eyelid movement depends on the antagonistic actions of orbicularis oculi muscle and levator aponeurosis. Blepharoptosis is an abnormal drooping of upper eyelid margin with the eye in primary position of gaze. Transconjunctival incisions for upper eyelid ptosis correction have been a welldeveloped technique. Conventional prognosis however depends on clinical observations and lacks of quantitatively analysis for the eyelid muscle controlling. This study examines the possibility of using the assessments of temporal correlation in surface electromyography (SEMG) as a quantitative description for the change of muscle controlling after operation. Eyelid SEMG was measured from patients with blepharoptosis preoperatively and postoperatively, as well as, for comparative study, from young and aged normal subjects. The data were analyzed using the detrended fluctuation analysis method. The results show that the temporal correlation of the SEMG signals can be characterized by two indices associated with the correlation properties in short and long time scales demarcated at 3 ms, corresponding to the time scale of neural response. Aging causes degradation of the correlation properties at both time scales, and patient group likely possess more serious correlation degradation in long-time regime which was improved moderately by the ptosis corrections. We propose that the temporal correlation in SEMG signals may be regarded as an indicator for evaluating the performance of eyelid muscle controlling in postoperative recovery. (C) 2016 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectTransconjunctival incisionen_US
dc.subjectDetrended fluctuation analysisen_US
dc.subjectBlepharoptosisen_US
dc.subjectSurface electromyographyen_US
dc.titleSurface electromyography analysis of blepharoptosis correction by transconjunctival incisionsen_US
dc.identifier.doi10.1016/j.jelekin.2016.02.009en_US
dc.identifier.journalJOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGYen_US
dc.citation.volume28en_US
dc.citation.spage23en_US
dc.citation.epage30en_US
dc.contributor.department生物科技學系zh_TW
dc.contributor.departmentDepartment of Biological Science and Technologyen_US
dc.identifier.wosnumberWOS:000375923000004en_US
顯示於類別:期刊論文