完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chen, Hung-Chi | en_US |
dc.contributor.author | Wu, Zhi-Xuan | en_US |
dc.contributor.author | Li, Chung-Yi | en_US |
dc.date.accessioned | 2017-04-21T06:49:27Z | - |
dc.date.available | 2017-04-21T06:49:27Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 2325-0313 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/136247 | - |
dc.description.abstract | In this paper, the average current method is proposed to detect the open-winding fault of three-phase permanent magnet synchronous motors (PMSMs). The characteristics and operational regions are studied. All the methods are implemented in FPGA-based system. The simulation and experimental results are provided to demonstrate the proposed method. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Open-Winding Fault | en_US |
dc.subject | Permanent-Magnet Synchronous Motor | en_US |
dc.title | Average Current Method to Detect Open-Winding Fault of Three-Phase Permanent Magnet Synchronous Motors | en_US |
dc.type | Proceedings Paper | en_US |
dc.identifier.journal | 2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE) | en_US |