標題: | Steady-state humic-acid-containing blanket in upflow suspended bed |
作者: | Sung, SS Lee, DJ Huang, C 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | flocculation clarifier;blanket;stability;humic acids drinking water |
公開日期: | 1-三月-2005 |
摘要: | We investigated the effects of turbidity and concentration of humic acid on the steady-state behavior of the blanket, which was coagulated using polyaluminum chloride (PACl) as coagulant. The three-dimensional solid-flux plot was constructed. Based on fixed PACl dosage, the iso-humic-acid solid-flux surfaces stacked that enveloped the feasible regime for the blanket bed. The steady-state point moved toward low solid flux and low solid fraction regime with decreasing initial raw water turbidity and/or increasing humic-acid concentration. Low water turbidity and high humic-acid concentration yielded a bulky blanket, with the former producing clean, and the latter turbid effluent. The presence of humic acid was thereby harmful to blanket strength, except for the case of low raw water turbidity. An optimal range of humic acid for blanket strength and clarification efficiency existed at 1 mg l(-1). Low level of humic acid is beneficial to blanket development with low-turbidity raw water. (c) 2005 Elsevier Ltd. All rights reserved. |
URI: | http://dx.doi.org/10.1016/j.watres.2004.12.030 http://hdl.handle.net/11536/13947 |
ISSN: | 0043-1354 |
DOI: | 10.1016/j.watres.2004.12.030 |
期刊: | WATER RESEARCH |
Volume: | 39 |
Issue: | 5 |
起始頁: | 831 |
結束頁: | 838 |
顯示於類別: | 期刊論文 |