dc.description.abstract | OBJECTIVE: This study proposed a method of using a modified micro-bubble generator with its ejection nozzle connected to an ergonomically designed soft teeth-tray for plaque removal. The applicability of this method was verified and the influence on plaque removal efficacy of some parameters of this device was clarified. METHODS: The micro-bubble generator used in this study has 5 rotation speed settings, 5 nozzle sizes, and a soft teeth-tray ejection pore diameters. These were used as independent variables to investigate their effect on the ejected flow volume, velocity and micro-bubble dimension, and how they eventually affect the plaque removal efficacy from a denture. RESULTS: When the micro-bubble generator coupled with large (4.8 mm) ejection pore teeth-tray and the largest (1.2 mm) nozzle diameter more than 98% of plaque can be removed; its applicability on cleaning denture can be verified. In general, the larger nozzle diameter and teeth-tray ejection pore diameter will remove more plaques; while the higher the flow velocity and the smaller the micro-bubble of the ejected stream, better cleaning efficacy can be achieved. CONCLUSION: The application of micro-bubble on plaque removal seems effective, although at this moment it is applied on denture cleaning. The finding of the influence of some critical design parameters of micro-bubble generator and variables of ejected stream can be referred to further design a new micro-bubble cleaner for effective plaque removal from the teeth in human oral cavity. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Micro-bubble generator | en_US |
dc.subject | the soft teeth-tray | en_US |
dc.subject | dental plaque removal | en_US |
dc.title | Application of micro-bubbles on oral care | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.3233/THC-171018 | en_US |
dc.identifier.journal | TECHNOLOGY AND HEALTH CARE | en_US |
dc.citation.volume | 25 | en_US |
dc.citation.spage | 1195 | en_US |
dc.citation.epage | 1200 | en_US |
dc.contributor.department | 應用藝術研究所 | zh_TW |
dc.contributor.department | Institute of Applied Arts | en_US |
dc.identifier.wosnumber | WOS:000418063500019 | en_US |
Appears in Collections: | Articles |