完整後設資料紀錄
DC 欄位語言
dc.contributor.authorZhu, Chen-Xien_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2018-08-21T05:53:10Z-
dc.date.available2018-08-21T05:53:10Z-
dc.date.issued2018-01-01en_US
dc.identifier.issn0947-7411en_US
dc.identifier.urihttp://dx.doi.org/10.1007/s00231-017-2100-xen_US
dc.identifier.urihttp://hdl.handle.net/11536/144346-
dc.description.abstractThis study proposes a numerical model for plate heat exchanger that is capable of handling supercritical CO2 fluid. The plate heat exchangers under investigation include Z-type (1-pass), U-type (1-pass), and 1-2 pass configurations. The plate spacing is 2.9 mm with a plate thickness of 0.8 mm, and the size of the plate is 600 mm wide and 218 mm in height with 60 degrees chevron angle. The proposed model takes into account the influence of gigantic change of CO2 properties. The simulation is first compared with some existing data for water-to-water plate heat exchangers with good agreements. The flow distribution, pressure drop, and heat transfer performance subject to the supercritical CO2 in plate heat exchangers are then investigated. It is found that the flow velocity increases consecutively from the entrance plate toward the last plate for the Z-type arrangement, and this is applicable for either water side or CO2 side. However, the flow distribution of the U-type arrangement in the water side shows opposite trend. Conversely, the flow distribution for U-type arrangement of CO2 depends on the specific flow ratio (C*). A lower C* like 0.1 may reverse the distribution, i.e. the flow velocity increases moderately alongside the plate channel like Z-type while a large C* of 1 would resemble the typical distribution in water channel. The flow distribution of CO2 side at the first and last plate shows a pronounced drop/surge phenomenon while the channels in water side does not reveal this kind of behavior. The performance of 2-pass plate heat exchanger, in terms of heat transfer rate, is better than that of 1-pass design only when C* is comparatively small (C* < 0.5). Multi-pass design is more effective when the dominant thermal resistance falls in the CO2 side.en_US
dc.language.isoen_USen_US
dc.titleA numerical study of the supercritical CO2 plate heat exchanger subject to U-type, Z-type, and multi-pass arrangementsen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s00231-017-2100-xen_US
dc.identifier.journalHEAT AND MASS TRANSFERen_US
dc.citation.volume54en_US
dc.citation.spage69en_US
dc.citation.epage79en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000419670500007en_US
顯示於類別:期刊論文