完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Hsu, Ya-Tzu | en_US |
dc.contributor.author | Li, Jia-Xiong | en_US |
dc.contributor.author | Lu, Ming-Chang | en_US |
dc.date.accessioned | 2018-08-21T05:53:16Z | - |
dc.date.available | 2018-08-21T05:53:16Z | - |
dc.date.issued | 2018-02-25 | en_US |
dc.identifier.issn | 1359-4311 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.applthermaleng.2017.12.067 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/144471 | - |
dc.description.abstract | Continual increases in the functionality and miniaturization of electronic devices have resulted in a rapid increase in the power density of such devices. Thus, an efficient cooling technology is required to maximize heat dissipation and prevent electronic failure. Immersion cooling is a promising technique for the thermal management of high-power-density electronics. However, common working fluids in immersion cooling have high global warming potential, and the heat transfer performance of immersion cooling requires improvement to achieve efficient cooling of state-of-the-art high-power-density electronics. In this study, Novec 649, which has low global warming potential and a low boiling point, was applied as a working fluid for immersion cooling. A Si nanowire (SiNW) array, Si micropillar (SiMP) array, and Si nanowires on a Si micropillar (SiNW/MP) two-tier structure were employed to enhance boiling performance. The SiMP surface exhibited the highest critical heat flux (CHF) of 23.5 +/- 1.3 W/cm(2), whereas the SiNW surface exhibited the lowest CHF but a relatively high heat transfer coefficient (HTC). The SiNW/MP surface exhibited the highest HTC of 23611.7 +/- 1586.2 W/m(2) K and a relatively large CHF of 17.4 +/- 1.2 W/cm(2). Compared with a plain SiO2 surface, the CHF and HTC of the SiNW/MP two-tier structure could be enhanced by 30% and 455%, respectively. These results suggest that the SiNW/MP surface is effective for enhancing immersion cooling. (C) 2017 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Boiling heat transfer | en_US |
dc.subject | Immersion cooling | en_US |
dc.subject | Novec 649 | en_US |
dc.subject | Critical heat flux | en_US |
dc.subject | Heat transfer coefficient | en_US |
dc.subject | Two-tier structure | en_US |
dc.title | Enhanced immersion cooling using two-tier micro- and nano-structures | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.applthermaleng.2017.12.067 | en_US |
dc.identifier.journal | APPLIED THERMAL ENGINEERING | en_US |
dc.citation.volume | 131 | en_US |
dc.citation.spage | 864 | en_US |
dc.citation.epage | 873 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000424173500078 | en_US |
顯示於類別: | 期刊論文 |