Full metadata record
DC FieldValueLanguage
dc.contributor.authorKobayashi, Takayoshien_US
dc.contributor.authorKawasumi, Koshien_US
dc.contributor.authorMiyazaki, Junen_US
dc.contributor.authorNakata, Kazuakien_US
dc.date.accessioned2018-08-21T05:53:31Z-
dc.date.available2018-08-21T05:53:31Z-
dc.date.issued2018-04-01en_US
dc.identifier.issn1340-6000en_US
dc.identifier.urihttp://dx.doi.org/10.1007/s10043-018-0416-5en_US
dc.identifier.urihttp://hdl.handle.net/11536/144807-
dc.description.abstractOptical pump-probe microscopy can provide images by detecting changes in probe light intensity induced by stimulated emission, photoinduced absorbance change, or photothermal-induced refractive index change in either transmission or reflection mode. Photothermal microscopy, which is one type of optical pump-probe microscopy, has intrinsically super resolution capability due to the bilinear dependence of signal intensity of pump and probe. We introduce new techniques for further resolution enhancement and fast imaging in photothermal microscope. First, we introduce a new pupil filter, an inverse-annular pupil filter in a pump-probe photothermal microscope, which provides resolution enhancement in three dimensions. The resolutions are proved to be improved in lateral and axial directions by imaging experiment using 20-nm gold nanoparticles. The improvement in X (perpendicular to the common pump and probe polarization direction), Y (parallel to the polarization direction), and Z (axial direction) are by 15 +/- 6, 8 +/- 8, and 21 +/- 2% from the resolution without a pupil filter. The resolution enhancement is even better than the calculation using vector field, which predicts the corresponding enhancement of 11, 8, and 6%. The discussion is made to explain the unexpected results. We also demonstrate the photothermal imaging of thick biological samples (cells from rabbit intestine and kidney) stained with hematoxylin and eosin dye with the inverse-annular filter. Second, a fast, high-sensitivity photothermal microscope is developed by implementing a spatially segmented balanced detection scheme into a laser scanning microscope using a Galvano mirror. We confirm a 4.9 times improvement in signal-to-noise ratio in the spatially segmented balanced detection compared with that of conventional detection. The system demonstrates simultaneous bi-modal photothermal and confocal fluorescence imaging of transgenic mouse brain tissue with a pixel dwell time of 20 mu s. The fluorescence image visualizes neurons expressing yellow fluorescence proteins, while the photothermal signal detected endogenous chromophores in the mouse brain, allowing 3D visualization of the distribution of various features such as blood cells and fine structures most probably due to lipids. This imaging modality was constructed using compact and cost-effective laser diodes, and will thus be widely useful in the life and medical sciences. Third, we have made further resolution improvement of high-sensitivity laser scanning photothermal microscopy by applying non-linear detection. By this, the new method has super resolution with 61 and 42% enhancement from the diffraction limit values of the probe and pump wavelengths, respectively, by a second-order non-linear scheme and a high-frame rate in a laser scanning microscope. The maximum resolution is determined to be 160 nm in the second-order non-linear detection mode and 270 nm in the linear detection mode by the PT signal of GNPs. The pixel rate and frame rate for 300 x 300 pixel image are 50 mu s and 4.5 s, respectively. The pixel and frame rate are shorter than the rates, those are 1 ms and 100 s, using the piezo-driven stage system.en_US
dc.language.isoen_USen_US
dc.subjectNonlinear microscopyen_US
dc.subjectScanning microscopyen_US
dc.subjectThree-dimensional microscopyen_US
dc.titleResolution enhancement of pump-probe microscope with an inverse-annular filteren_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s10043-018-0416-5en_US
dc.identifier.journalOPTICAL REVIEWen_US
dc.citation.volume25en_US
dc.citation.spage271en_US
dc.citation.epage294en_US
dc.contributor.department電子物理學系zh_TW
dc.contributor.departmentDepartment of Electrophysicsen_US
dc.identifier.wosnumberWOS:000429371200011en_US
Appears in Collections:Articles