完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Cheng, Chang-Chieh | en_US |
dc.contributor.author | Ching, Yu-Tai | en_US |
dc.contributor.author | Ko, Pai-Hung | en_US |
dc.contributor.author | Hwu, Yeukuang | en_US |
dc.date.accessioned | 2018-08-21T05:53:49Z | - |
dc.date.available | 2018-08-21T05:53:49Z | - |
dc.date.issued | 2018-06-29 | en_US |
dc.identifier.issn | 2045-2322 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1038/s41598-018-28149-8 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/145190 | - |
dc.description.abstract | An error in tomographic reconstruction parameters can result considerable artifacts in the reconstructed image, particularly in micro-computed tomography and nano-computed tomography. This study involved designing an automatic method for efficiently correcting errors resulting from incorrectly determined rotational axes and projection angles. In this method, errors are corrected by minimizing the "total variation" of a reconstructed image, and minimization is accomplished by using the gradient descent method. Compared with two previous methods, the proposed method achieved the best reconstruction results. | en_US |
dc.language.iso | en_US | en_US |
dc.title | Correction of center of rotation and projection angle in synchrotron X-ray computed tomography | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1038/s41598-018-28149-8 | en_US |
dc.identifier.journal | SCIENTIFIC REPORTS | en_US |
dc.citation.volume | 8 | en_US |
dc.contributor.department | 資訊工程學系 | zh_TW |
dc.contributor.department | Department of Computer Science | en_US |
dc.identifier.wosnumber | WOS:000436789500071 | en_US |
顯示於類別: | 期刊論文 |