dc.description.abstractIn this paper, a real-time, contactless pulse-based ultra-wideband (UWB) radar sensor was used to precisely detect the movement of the robotic arm, heartbeats, and respiration activities. To increase the object tracking resolution, an algorithm using adaptive and digitalized post-calibration techniques were proposed and tested. Both the radiated and reflected analog pulses were converted to digital signals by a low-noise comparator and its buffer for the time interval and distance detection. Moreover, the dynamic and calibrated tracking mechanism was incorporated into the algorithm for improving tracking accuracy and to continuously localize an object's vibration. The measured performance revealed that the proposed method successfully achieved mu m movement precision, thus providing its excellent tracking ability. We performed three different experimental tests to demonstrate the UWB radar's viability. First, the radar was employed to detect the undesired structural vibration of a delta robotic arm, which was subjected to high acceleration and structural flexibility. The measured results indicated that the accuracy of 100 mu m can be achieved at a 10 Hz vibration frequency. Next, the apnea alarm was tested, which included an embedded sensitive sensor in the smart mattress in order to execute long-term physiological monitoring. The apnea was mitigated by auto-adjusting the patient's sleeping posture on the mattress when the UWB sensor detected the apnea condition. The final experiment using the radar sensor was to monitor human vital signs, such as heart and breathing rates, simultaneously. In comparison with a commercial electrocardiography instrument, this radar sensor measured 73.2 bpm with only 1.2% deviation. Our results shown that the contactless UWB sensor performs superbly and is well-suited for monitoring physiological parameters.en_US
dc.language.isoen_USen_US
dc.subjectUWB radaren_US
dc.subjectvital-sign monitoringen_US
dc.subjectreal-timeen_US
dc.subjectnoncontacten_US
dc.subjectsensoren_US
dc.subjectcalibrationen_US
dc.titleReal-Time and Noncontact Impulse Radio Radar System for mu m Movement Accuracy and Vital-Sign Monitoring Applicationsen_US
dc.typeArticleen_US
dc.identifier.doi10.1109/JSEN.2017.2670919en_US
dc.identifier.journalIEEE SENSORS JOURNALen_US
dc.citation.volume17en_US
dc.citation.spage2349en_US
dc.citation.epage2358en_US
dc.contributor.department電信工程研究所zh_TW
dc.contributor.departmentInstitute of Communications Engineeringen_US
dc.identifier.wosnumberWOS:000398890800007en_US
顯示於類別:期刊論文