完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chiou, Jin-Chern | en_US |
dc.contributor.author | Hsu, Shun-Hsi | en_US |
dc.contributor.author | Liao, Yu-Te | en_US |
dc.contributor.author | Huang, Yu-Chieh | en_US |
dc.contributor.author | Yeh, Guan-Ting | en_US |
dc.contributor.author | Kuei, Cheng-Kai | en_US |
dc.contributor.author | Dai, Kai-Shiun | en_US |
dc.date.accessioned | 2018-08-21T05:54:07Z | - |
dc.date.available | 2018-08-21T05:54:07Z | - |
dc.date.issued | 2016-09-01 | en_US |
dc.identifier.issn | 2168-2194 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1109/JBHI.2016.2594058 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/145595 | - |
dc.description.abstract | This paper presents a wireless on-lens intraocular pressure monitoring system, comprising a capacitance-to-digital converter and a wirelessly powered radio-frequency identification (RFID)-compatible communication system, for sensor control and data communication. The capacitive sensor was embedded on a soft contact lens of 200 mu m thickness using commercially available biocompatible lens material, to improve compliance and reduce user discomfort. The sensor chip was shown to achieve effective number of bits greater than 10 over a capacitance range up to 50 pF while consuming only 64-mu W power. The on-lens capacitive sensor could detect dielectric variation caused by changes in water content from a distance of 2 cm by using incident power from an RFID reader at 20 dBm. The maximum detectable distance was 11 cm with 30-dBm incident RF power. The rise in eye tissue temperature under 30-dBm RF exposure over an interval of 1 s was simulated and found to be less than 0.01 degrees C. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Capacitance-to-digital converter (CDC) | en_US |
dc.subject | capacitive sensor | en_US |
dc.subject | soft contact lens | en_US |
dc.subject | UHF RFID Class1 Gen2 | en_US |
dc.title | Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1109/JBHI.2016.2594058 | en_US |
dc.identifier.journal | IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS | en_US |
dc.citation.volume | 20 | en_US |
dc.contributor.department | 電機工程學系 | zh_TW |
dc.contributor.department | 電控工程研究所 | zh_TW |
dc.contributor.department | Department of Electrical and Computer Engineering | en_US |
dc.contributor.department | Institute of Electrical and Control Engineering | en_US |
dc.identifier.wosnumber | WOS:000384000700002 | en_US |
顯示於類別: | 期刊論文 |