完整後設資料紀錄
DC 欄位語言
dc.contributor.authorSun, Chien-Hungen_US
dc.contributor.authorTseng, Chih-Yungen_US
dc.contributor.authorYang, Kai-Shingen_US
dc.contributor.authorWu, Shih-Kuoen_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2018-08-21T05:54:15Z-
dc.date.available2018-08-21T05:54:15Z-
dc.date.issued2017-07-01en_US
dc.identifier.issn0735-1933en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.icheatmasstransfer.2017.04.005en_US
dc.identifier.urihttp://hdl.handle.net/11536/145714-
dc.description.abstractThis study examines the influence of evacuation pressure on the startup and overall performance of pulsating heat pipes (PHP). The outer diameter of the copper tube is 3 mm and 2 mm (double tube design) having a wall thickness of 0.3 mm and 0.2 mm, respectively. The working fluids in this study include water and HFE-7000 with filling ratios around 50%, and the evacuation pressure ranging from 0.01 Torr to atmosphere pressure. For an evacuation pressure of 0.01 Torr at a supplied power of 80 W, the thermal resistance of the PHP filling with water is 0.928 K/W while it is 1.161 K/W for HFE-7000. However, the trend is reversed and the thermal resistance for HFE-7000 is lower than water when the evacuation pressure is increased over 100 Torr. The corresponding effective thermal conductivity of waterfilling PHP reaches 51,448 W/m K in comparison with 12,692 W/m K for HFE-7000. However, the effective thermal conductivity for waterfilling PHP drops appreciably with rising evacuation pressure, and the PHP is not functional at the atmosphere pressure. Conversely, although the effective thermal conductivity for HFE-7000 PHP still drops with the rise of evacuation pressure, the HFE-7000 PHP is still in operation even without any evacuation. The gigantic difference in the startup and performance of PHP is related to the solubility of noncondensable gas amid water and HFE-7000.en_US
dc.language.isoen_USen_US
dc.subjectPulsating heat pipeen_US
dc.subjectWateren_US
dc.subjectHFE-7000en_US
dc.subjectEvacuation pressureen_US
dc.subjectThermal resistanceen_US
dc.titleInvestigation of the evacuation pressure on the performance of pulsating heat pipeen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.icheatmasstransfer.2017.04.005en_US
dc.identifier.journalINTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFERen_US
dc.citation.volume85en_US
dc.citation.spage23en_US
dc.citation.epage28en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000404309200003en_US
顯示於類別:期刊論文