標題: | Perturbation On-time (POT) Control and Inhibit Time Control (ITC) in Suppression of THD of Power Factor Correction (PFC) Design |
作者: | Tsai, Jen-Chieh Chen, Chi-Lin Chen, Yi-Ting Ni, Chia-Lung Chen, Chun-Yen Chen, Ke-Horng Chen, Chih-Jen Pan, Heng-Lin 電控工程研究所 Institute of Electrical and Control Engineering |
關鍵字: | perturbation on-time control (POT);total harmonic distortion (THD);power factor correction (PFC);and inhibit time control (ITC) |
公開日期: | 2011 |
摘要: | The paper presented the perturbation on-time (POT) control technique to suppress the total harmonic distortion (THD) to improve the performance of the power factor correction (PFC) in the AC-DC converter. Simultaneously, it can improve the efficiency through the proposed inhibit time control (ITC) mechanism at low AC input voltage. The test circuit fabricated in TSMC 800V UHV process can show the highly-integrated PFC controller. Experimental results demonstrate low THD of 8%, which results in high PF of 99%. Besides, high efficiency of 95% can be ensured at the output power of 90W. |
URI: | http://hdl.handle.net/11536/14572 |
ISBN: | 978-1-4577-0223-5 |
期刊: | 2011 IEEE CUSTOM INTEGRATED CIRCUITS CONFERENCE (CICC) |
顯示於類別: | 會議論文 |