完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLu, HCen_US
dc.contributor.authorTsai, CJen_US
dc.date.accessioned2019-04-02T05:58:52Z-
dc.date.available2019-04-02T05:58:52Z-
dc.date.issued1998-12-01en_US
dc.identifier.issn0278-6826en_US
dc.identifier.urihttp://dx.doi.org/10.1080/02786829808965587en_US
dc.identifier.urihttp://hdl.handle.net/11536/147824-
dc.description.abstractFiltration curves and pulse-jet cleaning performance of different design and operating conditions of a pilot-scale pulse-jet baghouse are investigated. The effective residual pressure loss is used as an index of bag cleaning effect, while the average pulse overpressure inside the bag is used as an index of bag cleaning intensity. It is found that filtration curves vary with the initial tank pressure and the nozzle diameter of the bag cleaning system. The filtration time increases with increasing initial tank pressure or nozzle diameter. However, a critical value of the tank pressure exists for an effective bag cleaning. It is also found that a critical effective residual pressure loss value exists for the pulse-jet cleaning system. Too large an initial tank pressure and nozzle diameter result in a waste of cleaning energy. The addition of a venturi increases the average pulse overpressure appreciably, hence increasing the cleaning effect. A venturi is suggested to be installed to increase the bag cleaning effect and maximize cleaning energy in this study. (C) 1998 American Association for Aerosol Research.en_US
dc.language.isoen_USen_US
dc.titleA pilot-scale study of the design and operation parameters of a pulse-jet baghouseen_US
dc.typeArticleen_US
dc.identifier.doi10.1080/02786829808965587en_US
dc.identifier.journalAEROSOL SCIENCE AND TECHNOLOGYen_US
dc.citation.volume29en_US
dc.citation.spage510en_US
dc.citation.epage524en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000077037700004en_US
dc.citation.woscount20en_US
顯示於類別:期刊論文