完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Liao, Bo-Xi | en_US |
dc.contributor.author | Tseng, Neng-Chun | en_US |
dc.contributor.author | Li, Ziyi | en_US |
dc.contributor.author | Liu, Yingshu | en_US |
dc.contributor.author | Chen, Jen-Kun | en_US |
dc.contributor.author | Tsai, Chuen-Jinn | en_US |
dc.date.accessioned | 2019-04-02T05:59:38Z | - |
dc.date.available | 2019-04-02T05:59:38Z | - |
dc.date.issued | 2018-07-20 | en_US |
dc.identifier.issn | 1388-0764 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1007/s11051-018-4302-7 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/147894 | - |
dc.description.abstract | This study characterized the process by product particles (mostly nanoparticles) released during the preventive maintenance of semiconductor fabrication facilities, such as chemical mechanical planarization (CMP), plasma-enhanced chemical vapor deposition (PECVD), and ion implantation. Manual sampling and real-time measurements with direct reading instruments were conducted to assess the exposure levels of nanoparticles and their physical and chemical properties. Significant amount of nanoparticles were observed in the breathing zone of the workers during the maintenance of the PECVD and ion implanters with the peak number concentrations as high as 6,470,000 and 65,444 #/cm(3), respectively, indicating that the deposited residual chemicals in the reaction chambers were released as airborne nanoparticles by the maintenance activities. In contrast, nanoparticles released during the maintenance of the local scrubber, CMP, and replacing CMP slurry drums were insignificant. Causes of the particle release were discussed and suggestions were made to mitigate the nanoparticle release and reduce the exposure levels. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Occupational exposure assessment | en_US |
dc.subject | Nanoparticles | en_US |
dc.subject | Semiconductor fabrication | en_US |
dc.subject | Preventive maintenance | en_US |
dc.subject | Ion implanter | en_US |
dc.subject | PECVD | en_US |
dc.subject | Environmental and health effects | en_US |
dc.title | Exposure assessment of process by-product nanoparticles released during the preventive maintenance of semiconductor fabrication facilities | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1007/s11051-018-4302-7 | en_US |
dc.identifier.journal | JOURNAL OF NANOPARTICLE RESEARCH | en_US |
dc.citation.volume | 20 | en_US |
dc.contributor.department | 環境工程研究所 | zh_TW |
dc.contributor.department | Institute of Environmental Engineering | en_US |
dc.identifier.wosnumber | WOS:000439529000004 | en_US |
dc.citation.woscount | 0 | en_US |
顯示於類別: | 期刊論文 |