完整後設資料紀錄
DC 欄位語言
dc.contributor.authorThi-Cuc Leen_US
dc.contributor.authorShukla, Krishna Kumaren_US
dc.contributor.authorSung, Jung-Cheen_US
dc.contributor.authorLi, Ziyien_US
dc.contributor.authorYeh, Huajunen_US
dc.contributor.authorHuang, Weien_US
dc.contributor.authorTsai, Chuen-Jinnen_US
dc.date.accessioned2019-04-02T05:59:01Z-
dc.date.available2019-04-02T05:59:01Z-
dc.date.issued2019-03-04en_US
dc.identifier.issn0278-6826en_US
dc.identifier.urihttp://dx.doi.org/10.1080/02786826.2018.1559919en_US
dc.identifier.urihttp://hdl.handle.net/11536/149017-
dc.description.abstractThe louvered 16.7 L min(-1) PM10 inlet is commonly used in PM10 and PM2.5 FRM samplers or FEM monitors. Its sampling efficiency is influenced by particle bounce, re-entrainment, and overloading since the PM10 inlet contains a PM10 impactor with an uncoated impaction surface. In this study, a modified PM10 (M-PM10) inlet with an oil-soaked glass fiber filter substrate supported by an oil-soaked porous metal disc was developed to eliminate the particle bounce and overloading effects. The oiled M-PM10 inlet and the traditional PM10 inlets with and without grease coating were collocated at the field for long-term comparison tests. The results show that the traditional uncoated PM10 inlet which is cleaned initially but not cleaned daily afterwards oversamples PM10 concentration after one 24-h sampling day and has the high positive average sampling bias during 14 sampling days due to particle bounce and re-entrainment. The grease-coated PM10 inlet without daily cleaning shows a better performance with a smaller sampling bias, but it still oversamples PM10 concentrations after the first three 24-h sampling days and then undersamples after 10 sampling days due to particle bounce and overloading effects, respectively. In comparison, the M-PM10 inlet shows a good performance with a small average sampling bias during 35 sampling days since vacuum oil wicks up through the deposit to eliminate particle bounce and overloading. It is suggested that the oiled M-PM10 inlet can be used to replace the traditional EPA PM10 inlet and for long-term sampling of over 1 month without the frequent maintenance need. Copyright (c) 2019 American Association for Aerosol Researchen_US
dc.language.isoen_USen_US
dc.titleSampling efficiency of low-volume PM10 inlets with different impaction substratesen_US
dc.typeArticleen_US
dc.identifier.doi10.1080/02786826.2018.1559919en_US
dc.identifier.journalAEROSOL SCIENCE AND TECHNOLOGYen_US
dc.citation.volume53en_US
dc.citation.spage295en_US
dc.citation.epage308en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000461181200006en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文