完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Ammar, Syed Muhammad | en_US |
dc.contributor.author | Abbas, Naseem | en_US |
dc.contributor.author | Abbas, Saleem | en_US |
dc.contributor.author | Ali, Hafiz Muhammad | en_US |
dc.contributor.author | Hussain, Iftikhar | en_US |
dc.contributor.author | Janjua, Muhammad Mansoor | en_US |
dc.contributor.author | Sajjad, Uzair | en_US |
dc.contributor.author | Dahiya, Anurag | en_US |
dc.date.accessioned | 2019-05-02T00:25:54Z | - |
dc.date.available | 2019-05-02T00:25:54Z | - |
dc.date.issued | 2019-05-01 | en_US |
dc.identifier.issn | 0017-9310 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.ijheatmasstransfer.2019.01.047 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/151630 | - |
dc.description.abstract | Condensation heat transfer coefficient of R134a was obtained in multi-port micro channel smooth and grooved flat tubes of automotive heat exchanger. The test consisted of two smooth and one grooved tube. The test range covered mass flux 490-1600 kg/m(2) s, heat flux 5.5-19 kW/m(2) and saturation temperature 51-68 degrees C. Results revealed that condensation heat transfer coefficient increased with an increment of mass flux, vapor quality and decreased with the increase of saturation temperature. The effect of heat flux on heat transfer coefficient was negligible. The grooved tube showed larger heat transfer coefficient than that of smooth tubes. A comparison of the present data of flat tube with existing correlations revealed that the heat transfer coefficient was not reasonably predicted, therefore new correlation was developed for heat transfer coefficient that predicted 86% data within +/- 30% with a mean error of 16%. (C) 2019 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Automotive heat exchanger | en_US |
dc.subject | Flattened tube | en_US |
dc.subject | R134a | en_US |
dc.subject | Heat transfer coefficient | en_US |
dc.subject | Pure two-phase vapor | en_US |
dc.title | Condensing heat transfer coefficients of R134a in smooth and grooved multiport flat tubes of automotive heat exchanger: An experimental investigation | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.ijheatmasstransfer.2019.01.047 | en_US |
dc.identifier.journal | INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER | en_US |
dc.citation.volume | 134 | en_US |
dc.citation.spage | 366 | en_US |
dc.citation.epage | 376 | en_US |
dc.contributor.department | 交大名義發表 | zh_TW |
dc.contributor.department | National Chiao Tung University | en_US |
dc.identifier.wosnumber | WOS:000462418300033 | en_US |
dc.citation.woscount | 0 | en_US |
顯示於類別: | 期刊論文 |