完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChung, Hwei-Mingen_US
dc.contributor.authorLi, Wen-Taien_US
dc.contributor.authorYuen, Chauen_US
dc.contributor.authorChung, Wei-Hoen_US
dc.contributor.authorZhang, Yanen_US
dc.contributor.authorWen, Chao-Kaien_US
dc.date.accessioned2019-08-02T02:15:30Z-
dc.date.available2019-08-02T02:15:30Z-
dc.date.issued2019-07-01en_US
dc.identifier.issn1949-3053en_US
dc.identifier.urihttp://dx.doi.org/10.1109/TSG.2018.2865316en_US
dc.identifier.urihttp://hdl.handle.net/11536/152197-
dc.description.abstractMalicious attacks in the power system can eventually result in a large-scale cascade failure if not rectified in a timely manner. These attacks, which are traditionally classified into physical and cyber attacks, can be avoided by using the latest advanced detection mechanisms. However, a new threat called cyber-physical attacks jointly targets both the physical and cyber layers of the system to interfere with the operations of the power grid is more malicious than traditional attacks. In this paper, we propose a new cyber-physical attack strategy where the transmission line is first physically disconnected, the line-outage event is masked to mislead the control center into detecting this as an obvious line outage at a different position in the local area of the power system. Therefore, the topology information in the control center is interfered with as a result of our attack. We also propose a novel procedure for selecting vulnerable lines and analyze the observability of our proposed framework. Our proposed method can effectively and continuously deceive the control center into detecting fake line-outage positions, and thereby increase the chance of cascade failure because the attention is given to the fake outage. The simulation results validate the efficiency of our proposed attack strategy.en_US
dc.language.isoen_USen_US
dc.subjectCyber-physical systemen_US
dc.subjectjoint attacksen_US
dc.subjectsmart griden_US
dc.subjectpower line outagesen_US
dc.subjectpower flowen_US
dc.titleLocal Cyber-Physical Attack for Masking Line Outage and Topology Attack in Smart Griden_US
dc.typeArticleen_US
dc.identifier.doi10.1109/TSG.2018.2865316en_US
dc.identifier.journalIEEE TRANSACTIONS ON SMART GRIDen_US
dc.citation.volume10en_US
dc.citation.issue4en_US
dc.citation.spage4577en_US
dc.citation.epage4588en_US
dc.contributor.department交大名義發表zh_TW
dc.contributor.departmentNational Chiao Tung Universityen_US
dc.identifier.wosnumberWOS:000472577500096en_US
dc.citation.woscount4en_US
顯示於類別:期刊論文