標題: | An indoor light-activated 3D cone-shaped MoS2 bilayer-based NO gas sensor with PPb-level detection at room-temperature |
作者: | Chen, Yu-Ze Wang, Sheng-Wen Yang, Chun-Chuan Chung, Chieh-Han Wang, Yi-Chung Chen, Sung-Wen Huang Chen, Chia-Wei Su, Teng-Yu Lin, Heh-Nan Kuo, Hao-Chung Chueh, Yu-Lun 光電工程學系 光電工程研究所 Department of Photonics Institute of EO Enginerring |
公開日期: | 7-六月-2019 |
摘要: | Utilization of light to boost the performance of gas sensors allows us to operate sensor devices at room temperature. Here, we, for the first time, demonstrated an indoor light-activated 3D cone-shaped MoS2 bilayer-based NO gas sensor with ppb-level detection operated at room-temperature. Large-area coneshaped (CS)-MoS2 bilayers were grown by depositing 2 nm-thick MoO3 layers on a 2'' three-dimensional (3D) cone-patterned sapphire substrate (CPSS) followed by a sulfurization process via chemical vapor deposition. Because the exposed area of MoS2 bilayers is increased by 30%, the CS-MoS2 gas sensor (GS) demonstrated excellent performance with a response of 470% and a fast response time of 25 s after exposure to 1 ppm of NO gas illuminated by ultraviolet (UV) light with a wavelength of 365 nm. Such extraordinary performance at room temperature is attributed to the enhanced light absorption because of the light scattering effect caused by the 3D configuration and photo-desorption induced by UV illumination. For NO concentrations ranging from 2 ppm down to 0.06 ppm, the CS-MoS2 GS demonstrated a stable sensing behavior with a high response and fast response time (470% and 25 s at 2 ppm NO) because of the light absorption enhanced by the 3D structure and photo-desorption under constant UV illumination. The CS-MoS2 GS exhibits a high sensitivity (189.2 R% ppm-1), allowing the detection of NO gas at 0.06 ppm in 130 s. In addition, the 3D cone-shaped structure prolonged the presence of sulfur vapor around MoO3, allowing MoO3 to react with sulfur completely. Furthermore, the CS-MoS2 GS using an indoor lighting to detect NO gas at room temperature was demonstrated for the first time where the CS-MoS2 GS exhibits a stable cycling behavior with a high response (165% at 1 ppm NO) in 50 s; for concentration as low as 0.06 ppm, the response of 75% in 150 s can be achieved. |
URI: | http://dx.doi.org/10.1039/c8nr10157d http://hdl.handle.net/11536/152278 |
ISSN: | 2040-3364 |
DOI: | 10.1039/c8nr10157d |
期刊: | NANOSCALE |
Volume: | 11 |
Issue: | 21 |
起始頁: | 10410 |
結束頁: | 10419 |
顯示於類別: | 期刊論文 |