Full metadata record
DC FieldValueLanguage
dc.contributor.authorChen, Chui-Hsinen_US
dc.contributor.authorTsai, Yi-Rungen_US
dc.contributor.authorTang, Yaoen_US
dc.date.accessioned2019-10-05T00:08:39Z-
dc.date.available2019-10-05T00:08:39Z-
dc.date.issued2019-08-01en_US
dc.identifier.issn2092-7614en_US
dc.identifier.urihttp://dx.doi.org/10.12989/eas.2019.17.2.163en_US
dc.identifier.urihttp://hdl.handle.net/11536/152796-
dc.description.abstractFor Special Concentrically Braced Frame (SCBF), it is common that the damage concentrates at a certain story instead of spreading over all stories. Once the damage occurs, the soft-story mechanism is likely to take place and possibly to result in the failure of the whole system with more damage accumulation. In this study, we use a strongback column which is an additional structural component extending along the height of the building, to redistribute the excessive deformation of SCBF and activate more structural members to dissipate energy and thus avoid damage concentration and improve the seismic performance of SCBF. We tested one-third-scaled, three-story, double-story X SCBF specimens with static cyclic loading procedure. Three specimens, namely S73, S42 and S0, which represent different combinations of stiffness and strength factors a and beta for the strongback columns, were designed based on results of numerical simulations. Specimens S73 and S42 were the specimens with the strongback columns, and SO is the specimen without the strongback column. Test results show that the deformation distribution of Specimen S73 is more uniform and more brace members in three stories perform nonlinearly. Comparing Drift Concentration Factor (DCF), we can observe 29% and 11% improvement in Specimen S73 and S42, respectively. This improvement increases the nonlinear demand of the third-story braces and reduces that of the first-story braces where the demand used to be excessive, and, therefore, postpones the rupture of the first-story braces and enhances the ductility and energy dissipation capacity of the whole SCBF system.en_US
dc.language.isoen_USen_US
dc.subjectspecial concentrically braced frameen_US
dc.subjectsoft storyen_US
dc.subjectstrongback columnen_US
dc.subjectstatic cyclic loadingen_US
dc.subjectdrift concentration factoren_US
dc.subjectenergy dissipation capacityen_US
dc.titleCyclic testing of scaled three-story special concentrically braced frame with strongback columnen_US
dc.typeArticleen_US
dc.identifier.doi10.12989/eas.2019.17.2.163en_US
dc.identifier.journalEARTHQUAKES AND STRUCTURESen_US
dc.citation.volume17en_US
dc.citation.issue2en_US
dc.citation.spage163en_US
dc.citation.epage173en_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.identifier.wosnumberWOS:000486578500003en_US
dc.citation.woscount0en_US
Appears in Collections:Articles