完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLiao, Pei-Hanen_US
dc.contributor.authorYang, Hui-Hsienen_US
dc.contributor.authorWu, Pei-Chien_US
dc.contributor.authorAbu Bakar, Noor Hidayaten_US
dc.contributor.authorUrban, Pawel L.en_US
dc.date.accessioned2020-02-02T23:54:33Z-
dc.date.available2020-02-02T23:54:33Z-
dc.date.issued2020-01-07en_US
dc.identifier.issn0003-2700en_US
dc.identifier.urihttp://dx.doi.org/10.1021/acs.analchem.9b04380en_US
dc.identifier.urihttp://hdl.handle.net/11536/153521-
dc.description.abstractSimultaneous distillation-extraction (SDE) using the Likens-Nickerson apparatus is a convenient technique used to isolate volatile organic compounds (VOCs) from complex liquid matrices. The technique combines steam distillation with solvent extraction. While analytical extractions are normally followed by off-line separation/detection, it is advantageous to couple extractions on-line with separation and detection systems that are employed in the same analytical workflow. Here, we have coupled the Likens-Nickerson apparatus on-line with a gas chromatograph hyphenated with a mass spectrometer. For that purpose, we have devised an automated liquid transfer setup comprising a peristaltic pump, control unit, customized transfer vial with a drain port, and an autosampler arm to deliver liquid extract aliquots at defined time points. The on-line SDE-GC/MS system enables one to record real-time extraction profiles. These profiles reveal extraction kinetics of various VOCs present in the extracted samples. The data sets were fitted with the first order kinetic equation to obtain numeric values characterizing the extraction process (rate constants ranging from 0.21 to 0.01 min(-1) for the ethyl esters from C-6 to C-19). A comparison of on-line and off-line results reveals that the on-line system is more dependable, while the off-line analysis leads to artifacts. To demonstrate the operation of the on-line SDE-GC/MS system, we performed analyses of selected real samples (beer). The real-time data sets revealed extraction kinetics for VOCs present in these samples. The devised extraction-analysis system allows the analysts to make an evidence-based decision on the extraction time for different groups of analytes in order to maximize extraction yield and minimize analyte losses.en_US
dc.language.isoen_USen_US
dc.titleOn-Line Coupling of Simultaneous Distillation-Extraction Using the Likens-Nickerson Apparatus with Gas Chromatographyen_US
dc.typeArticleen_US
dc.identifier.doi10.1021/acs.analchem.9b04380en_US
dc.identifier.journalANALYTICAL CHEMISTRYen_US
dc.citation.volume92en_US
dc.citation.issue1en_US
dc.citation.spage1228en_US
dc.citation.epage1235en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.identifier.wosnumberWOS:000506719400121en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文