Full metadata record
DC FieldValueLanguage
dc.contributor.authorShaw, Fu-Zenen_US
dc.contributor.authorYang, Tsung-Fuen_US
dc.contributor.authorHuang, Chien-Chunen_US
dc.contributor.authorYeh, Keng-Hungen_US
dc.contributor.authorChang, Tao-Chihen_US
dc.contributor.authorLeu, Fang-Junen_US
dc.date.accessioned2014-12-08T15:21:39Z-
dc.date.available2014-12-08T15:21:39Z-
dc.date.issued2011-12-01en_US
dc.identifier.issn1016-2372en_US
dc.identifier.urihttp://dx.doi.org/10.1142/S1016237211002840en_US
dc.identifier.urihttp://hdl.handle.net/11536/15374-
dc.description.abstractPlanar electrode array is an important tool to evaluate perceptual or cognitive functions of the cortex and prosthetic applications. Many construction methods have been developed. To maximize the usefulness of an array electrode, a low-cost, precise, and flexible microelectrode array with low man power and short construction duration is crucial. In this study, we introduced an 8 x 8 microelectrode array on a flexible polyimide film through microelectronics fabrication. The array dimension was capable of covering the primary somatosensory cortex of a rat. The microelectrode array was insulated with biocompatible Parylene-C except of microelectrode tip. Each electrode tip was 66 mu m height and separated with 0.5 mm to refine a detail somatic sensory processing. In pentobarbital anesthetized rats, stable spontaneous brain activity was successfully recorded through the electrode array. In addition, positive peaks of somatosensory evoked potentials (SEPs) elicited by stimulating rat's whisker pad, forepaw, hindpaw, and tail were obviously and consistently recorded. Latencies of SEPs increased as caudal part of the body was stimulated. The SEPs from stimulation of 4 body parts revealed different spatiotemporal patterns, which indicated a somatotopic organization of the rat. Our results demonstrated the superiority of the planar microelectrode array on the application of simultaneous recording and analysis of the brain activity in rats.en_US
dc.language.isoen_USen_US
dc.subjectMicroelectrodeen_US
dc.subjectSomatotopic mapen_US
dc.subjectMEMSen_US
dc.subjectPlanaren_US
dc.subjectArrayen_US
dc.titleMULTICHANNEL PLANAR MICROELECTRODE ARRAY FOR SOMATIC MAPPING IN RATSen_US
dc.typeArticleen_US
dc.identifier.doi10.1142/S1016237211002840en_US
dc.identifier.journalBIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONSen_US
dc.citation.volume23en_US
dc.citation.issue6en_US
dc.citation.spage501en_US
dc.citation.epage508en_US
dc.contributor.department友訊交大聯合研發中心zh_TW
dc.contributor.departmentD Link NCTU Joint Res Ctren_US
dc.identifier.wosnumberWOS:000299087200008-
dc.citation.woscount0-
Appears in Collections:Articles