完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChen, Chin-Chungen_US
dc.contributor.authorLin, Ching-Kaien_US
dc.contributor.authorChang, Chen-Weien_US
dc.contributor.authorCheng, Yun-Chienen_US
dc.contributor.authorChen, Jia-Enen_US
dc.contributor.authorTsai, Sung-Linen_US
dc.contributor.authorChung, Tien-Kanen_US
dc.date.accessioned2020-03-02T03:23:30Z-
dc.date.available2020-03-02T03:23:30Z-
dc.date.issued2019-12-01en_US
dc.identifier.urihttp://dx.doi.org/10.3390/s19235105en_US
dc.identifier.urihttp://hdl.handle.net/11536/153765-
dc.description.abstractIn this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking endobronchoscope used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an endobronchoscope. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the endobronchoscope's guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage-pattern change, the location of the silicon-steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the endobronchoscope in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.en_US
dc.language.isoen_USen_US
dc.subjectpassive magnetic-flux concentratoren_US
dc.subjectmagneticen_US
dc.subjectelectromagneticen_US
dc.subjecttargetingen_US
dc.subjecttrackingen_US
dc.subjectlocatingen_US
dc.subjectendobronchoscopeen_US
dc.subjectendoscopeen_US
dc.subjectlung cancer tumoren_US
dc.subjectlesionen_US
dc.titlePassive Magnetic-Flux-Concentrator Based Electromagnetic Targeting System for Endobronchoscopyen_US
dc.typeArticleen_US
dc.identifier.doi10.3390/s19235105en_US
dc.identifier.journalSENSORSen_US
dc.citation.volume19en_US
dc.citation.issue23en_US
dc.citation.spage0en_US
dc.citation.epage0en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.department國際半導體學院zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.contributor.departmentInternational College of Semiconductor Technologyen_US
dc.identifier.wosnumberWOS:000507606200048en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文