標題: The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated With Flow Disturbance at the Venous Stenosis Location on Angiography
作者: Yang, Chih-Yu
Li, Ming-Chia
Lan, Chien-Wen
Lee, Wang-Jiun
Lee, Chen-Ju
Wu, Cheng-Hsueh
Tang, Jing-Min
Niu, Yang-Yao
Lin, Yao-Ping
Shiu, Yan-Ting
Cheung, Alfred K.
Lee, Yan-Hwa Wu
Lee, Oscar Kuang-Sheng
Chien, Shu
Tarng, Der-Cherng
生醫工程研究所
Institute of Biomedical Engineering
關鍵字: arteriovenous fistula;angiography;anastomotic angle;stenosis;computational fluid dynamics;disturbed flow
公開日期: 23-七月-2020
摘要: The juxta-anastomotic stenosis of an arteriovenous fistula (AVF) is a significant clinical problem in hemodialysis patients with no effective treatment. Previous studies of AV anastomotic angles on hemodynamics and vascular wall injury were based on computational fluid dynamics (CFD) simulations using standardized AVF geometry, not the real-world patient images. The present study is the first CFD study to use angiographic images with patient-specific outcome information, i.e., the exact location of the AVF stenotic lesion. We conducted the CFD analysis utilizing patient-specific AVF geometric models to investigate hemodynamic parameters at different locations of an AVF, and the association between hemodynamic parameters and the anastomotic angle, particularly at the stenotic location. We analyzed 27 patients who used radio-cephalic AVF for hemodialysis and received an angiographic examination for juxta-anastomotic stenosis. The three-dimensional geometrical model of each patient's AVF was built using the angiographic images, in which the shape and the anastomotic angle of the AVF were depicted. CFD simulations of AVF hemodynamics were conducted to obtain blood flow parameters at different locations of an AVF. We found that at the location of the stenotic lesion, the AV angle was significantly correlated with access flow disturbance (r= 0.739;p< 0.001) and flow velocity (r= 0.563;p= 0.002). Furthermore, the receiver operating characteristic (ROC) curve analysis revealed that the AV angle determines the lesion's flow disturbance with a high area under the curve value of 0.878. The ROC analysis also identified a cut-off value of the AV angle as 46.5 degrees, above or below which the access flow disturbance was significantly different. By applying CFD analysis to real-world patient images, the present study provides evidence that an anastomotic angle wider than 46.5 degrees might lead to disturbed flow generation, demonstrating a reference angle to adopt during the anastomosis surgery.
URI: http://dx.doi.org/10.3389/fbioe.2020.00846
http://hdl.handle.net/11536/155138
ISSN: 2296-4185
DOI: 10.3389/fbioe.2020.00846
期刊: FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY
Volume: 8
起始頁: 0
結束頁: 0
顯示於類別:期刊論文