dc.description.abstract | This paper presents the design of the coaxial heterogeneous hyperspectral system, concurrently sensing for the visible (YES) light and short-wave infrared (SWIR) light wavelengths under the same space axis. By the designed mechanism, this hyperspectral system can provide more hands and broader wavelengths in every scan. The adequate spectral information of the target makes the analysis more comprehensive. For this hyperspectral system, the spatial correction and spectral correction are required. The spatial correction deals with the spatial match between the VIS and SWIR data. Moreover, the spectral correction is to eliminate the different response of the YES and SWIR sensor. The purpose of these corrections was to verify the design and provide the accurate reflection spectrum. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | hyperspectral system | en_US |
dc.subject | VIS | en_US |
dc.subject | SWIR | en_US |
dc.subject | spectral correction | en_US |
dc.subject | hyperspectrometers | en_US |
dc.title | Development and verification of the coaxial heterogeneous hyperspectral system for the Wax Apple tree | en_US |
dc.type | Proceedings Paper | en_US |
dc.identifier.journal | 2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) | en_US |
dc.citation.spage | 613 | en_US |
dc.citation.epage | 617 | en_US |
dc.contributor.department | 分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department | 影像與生醫光電研究所 | zh_TW |
dc.contributor.department | 電控工程研究所 | zh_TW |
dc.contributor.department | Institute of Molecular Medicine and Bioengineering | en_US |
dc.contributor.department | Institute of Imaging and Biomedical Photonics | en_US |
dc.contributor.department | Institute of Electrical and Control Engineering | en_US |
dc.identifier.wosnumber | WOS:000568630900110 | en_US |
dc.citation.woscount | 0 | en_US |
Appears in Collections: | Conferences Paper |