Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chong, Ngot Swan | en_US |
dc.contributor.author | Lee, Jason J. S. | en_US |
dc.contributor.author | Kung, Wei-Hsiang | en_US |
dc.contributor.author | Chen, Chien-An | en_US |
dc.contributor.author | Hsieh, Chen-Hsi | en_US |
dc.contributor.author | Tien, Hui-Ju | en_US |
dc.contributor.author | Lin, Chi-Ta | en_US |
dc.contributor.author | Yeh, Hsin-Pei | en_US |
dc.contributor.author | Wu, Le-Jung | en_US |
dc.contributor.author | Huang, Hsien-Da | en_US |
dc.contributor.author | Shueng, Pei-Wei | en_US |
dc.date.accessioned | 2014-12-08T15:22:12Z | - |
dc.date.available | 2014-12-08T15:22:12Z | - |
dc.date.issued | 2011-12-01 | en_US |
dc.identifier.issn | 1350-4487 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.radmeas.2011.08.004 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/15719 | - |
dc.description.abstract | The purpose of this study is to demonstrate how to perform and define appropriate action levels for the intensity-modulated radiation therapy (IMRT) delivery quality assurance (DQA) for both linear accelerator (linac) and helical tomotherapy (HT) plans using a 2D array diode detector. MapCHECK (Sun Nuclear, Melbourne, FL, USA) was used to perform the DQA measurements of patient plans at various sites: brain, head and neck, chest, abdomen, pelvis, spine, bone and others. The measured and planned doses were compared using gamma analysis with a total dose discrepancy of 3% or a gradient difference of 3 mm criteria. DQAs for 507 HT and 380 linac-based IMRT plans were performed, and the mean diode percentage passing rates for 3%/3 mm criteria were 93.8% and 95.1% respectively. For HT delivery, 4.6% and 9.5% of the plans had the passing rates below 80% and 85%, while for linac-based IMRT, 7.4% of the plans had the passing rates lower than 90%. Applying confidence limit with multiplier of 1, action levels for passing rates of 87% and 90% are recommended for HT and IMRT plans respectively. (C) 2011 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | MapCHECK | en_US |
dc.subject | Intensity modulated radiation therapy | en_US |
dc.subject | Quality assurance | en_US |
dc.subject | Linear accelerator | en_US |
dc.subject | Helical Tomotherapy | en_US |
dc.title | Patient delivery quality assurance for linac-based IMRT and helical tomotherapy using solid state detectors | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.radmeas.2011.08.004 | en_US |
dc.identifier.journal | RADIATION MEASUREMENTS | en_US |
dc.citation.volume | 46 | en_US |
dc.citation.issue | 12 | en_US |
dc.citation.spage | 1993 | en_US |
dc.citation.epage | 1995 | en_US |
dc.contributor.department | 電子工程學系及電子研究所 | zh_TW |
dc.contributor.department | Department of Electronics Engineering and Institute of Electronics | en_US |
dc.identifier.wosnumber | WOS:000300459400157 | - |
dc.citation.woscount | 0 | - |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.