標題: Patient-oriented simulation based on Monte Carlo algorithm by using MRI data
作者: Chuang, Ching-Cheng
Lee, Yu-Tzu
Chen, Chung-Ming
Hsieh, Yao-Sheng
Liu, Tsan-Chi
Sun, Chia-Wei
光電工程學系
Department of Photonics
關鍵字: Patient-oriented simulation;Time-resolved Monte Carlo;Brain modeling;Spatial sensitivity profile
公開日期: 17-四月-2012
摘要: Background: Although Monte Carlo simulations of light propagation in full segmented three-dimensional MRI based anatomical models of the human head have been reported in many articles. To our knowledge, there is no patient-oriented simulation for individualized calibration with NIRS measurement. Thus, we offer an approach for brain modeling based on image segmentation process with in vivo MRI T1 three-dimensional image to investigate the individualized calibration for NIRS measurement with Monte Carlo simulation. Methods: In this study, an individualized brain is modeled based on in vivo MRI 3D image as five layers structure. The behavior of photon migration was studied for this individualized brain detections based on three-dimensional time-resolved Monte Carlo algorithm. During the Monte Carlo iteration, all photon paths were traced with various source-detector separations for characterization of brain structure to provide helpful information for individualized design of NIRS system. Results: Our results indicate that the patient-oriented simulation can provide significant characteristics on the optimal choice of source-detector separation within 3.3 cm of individualized design in this case. Significant distortions were observed around the cerebral cortex folding. The spatial sensitivity profile penetrated deeper to the brain in the case of expanded CSF. This finding suggests that the optical method may provide not only functional signal from brain activation but also structural information of brain atrophy with the expanded CSF layer. The proposed modeling method also provides multi-wavelength for NIRS simulation to approach the practical NIRS measurement. Conclusions: In this study, the three-dimensional time-resolved brain modeling method approaches the realistic human brain that provides useful information for NIRS systematic design and calibration for individualized case with prior MRI data.
URI: http://dx.doi.org/21
http://hdl.handle.net/11536/16344
ISSN: 1475-925X
DOI: 21
期刊: BIOMEDICAL ENGINEERING ONLINE
Volume: 11
Issue: 
結束頁: 
顯示於類別:期刊論文


文件中的檔案:

  1. 000304246800001.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。