dc.description.abstract | It is common for peristaltic micropumps to have large compression ratios. In the limit, the chamber of the pump is completely blocked by the membrane to prevent back flow. Different from this kind of pump, a micropump with small compression ratios is proposed in this study. With small oscillation amplitudes the membrane of the pump can reciprocate at high frequencies to improve its pumping flow. Both the multidimensional method and the lumped-element method are employed for analysis. For this kind of peristaltic micropump the working fluid is allowed to flow freely in the forward and backward directions. Therefore, the operating sequences for the high-compression ratio type of pumps are not appropriate. It is shown that the theoretical net flow rate is zero for the four-phase and six-phase modes of sequence and becomes negative for the three-phase mode unless regulators, such as the nozzle/diffusers, are incorporated to rectify the flow. However, this pump becomes very attractive by reversing the operating sequence of the three-phase mode because positive net flow is yielded. It is seen that with the reversed three-phase mode and the nozzle/diffuser as connecting channels, the pumping effectiveness is greatly enhanced. The pumps with both two chambers and three chambers are under consideration in the study. Copyright (c) 2011 John Wiley & Sons, Ltd. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | peristaltic micropump | en_US |
dc.subject | low compression ratio | en_US |
dc.subject | lumped-system analysis | en_US |
dc.subject | CFD simulation | en_US |
dc.title | A novel peristaltic micropump with low compression ratios | en_US |
dc.type | Article | en_US |
dc.identifier.journal | INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS | en_US |
dc.citation.volume | 69 | en_US |
dc.citation.issue | 8 | en_US |
dc.citation.epage | 1363 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000305183400004 | - |
dc.citation.woscount | 1 | - |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.