標題: Edge Contrast Failure Analysis on Vision Angle of Human Eyes for Curve Displays
作者: Wen, Bor-Jiunn
Liu, T. S.
機械工程學系
Department of Mechanical Engineering
關鍵字: Curve display;edge contrast failure analysis (ECFA);flexible cholesteric liquid crystal display;flexible-characteristic inspection system;vision angle of human eyes
公開日期: 1-七月-2012
摘要: For curve displays, the purpose of this study is to present edge contrast failure analysis (ECFA) method on the vision angle of human eyes. In order to analyze edge contrast of curve display images, a flexible cholesteric liquid crystal display is bent for different radii of curvature by using a flexible-characteristic inspection system. To simulate the human eye factors, a charge-coupled device colorimeter is utilized based on ECFA to analyze a maximum vision angle of human eyes with respect to curve displays under different radii of curvature. According to analysis results, a designer or maker of curve displays can design large-vision-angle and comfortable curve-display products for human being.
URI: http://hdl.handle.net/11536/16451
ISSN: 1551-319X
期刊: JOURNAL OF DISPLAY TECHNOLOGY
Volume: 8
Issue: 7
結束頁: 418
顯示於類別:期刊論文


文件中的檔案:

  1. 000305978900001.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。