Title: A micro membrane vibrator with thermally driven bimorph cantilever beams
Authors: Tsao, CC
Hsu, WY
機械工程學系
Department of Mechanical Engineering
Keywords: bimorph;membrane vibrator;micromachining
Issue Date: 1997
Abstract: A micro membrane vibrator consisting of bimorph cantilever beams and a membrane is designed, fabricated, and tested here. Due to the discrepancy of thermal expansion coefficients between different layers, the membrane moves with temperature change. The four-layer structure including SiO2-polysilicon-insulated SiO2-aluminum is fabricated with four masks. The numerical finite element program ANSYS 51 is used to investigate the behavior of different designs to have larger displacement and force. According to the testing results, we observe that our designs can induce the maximum Z-axis displacement up to 117 mu m when input power is 6.98 W. The working frequency is about 40 Hz when the amplitude is kept between 2 and 5 mu m approximately.
URI: http://hdl.handle.net/11536/19653
http://dx.doi.org/10.1117/12.293498
ISBN: 0-8194-2679-2
ISSN: 0277-786X
DOI: 10.1117/12.293498
Journal: SMART MATERIALS, STRUCTURES, AND INTEGRATED SYSTEMS
Volume: 3241
Begin Page: 195
End Page: 205
Appears in Collections:Conferences Paper


Files in This Item:

  1. 000071156200022.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.