Full metadata record
DC FieldValueLanguage
dc.contributor.authorHuang, Tzu-Yenen_US
dc.contributor.authorHuang, Jen-Hsienen_US
dc.contributor.authorWei, Hung-Yuen_US
dc.contributor.authorHo, Kuo-Chuanen_US
dc.contributor.authorChu, Chih-Weien_US
dc.date.accessioned2014-12-08T15:29:43Z-
dc.date.available2014-12-08T15:29:43Z-
dc.date.issued2013-05-15en_US
dc.identifier.issn0956-5663en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.bios.2012.10.047en_US
dc.identifier.urihttp://hdl.handle.net/11536/21343-
dc.description.abstractIn this study we performed electrochemical sensing using conductive carbon composite films containing reduced graphene oxide (rGO) and single-walled carbon nanotubes (SWCNTs) as electrode modifiers on glassy carbon electrodes (GCEs). Raman spectroscopy, transmission electron microscopy, atomic force microscopy, and scanning electron microscopy all suggested that the rGO acted as a surfactant, covering and smoothing out the surface, and that the SWCNTs acted as a conducting bridge to connect the isolated rGO sheets, thereby (i) minimizing the barrier for charge transfer between the rGO sheets and (ii) increasing the conductivity of the film. We used the rGO/SWCNT-modified GCE as a sensor to analyze hydrogen peroxide (H2O2) and beta-nicotinamide adenine dinucleotide (NADH), obtaining substantial improvements in electrochemical reactivity and detection limits relative to those obtained from rGO- and SWCNT-modified electrodes, presumably because of the higher conductivity and greater coverage on the GCE, due to pi-pi interactions originating from the graphitic structures of the rGO and SWCNTs. The electrocatalysis response was measured by cyclic voltammetry and amperometric current-time (i-t) curve techniques. The linear concentration range of H2O2 and NADH detection at rGO/SWCNT-modified electrode is 0.5-5 M and 20-400 mu M. The sensitivity for H2O2 and NADH detection is 2732.4 and 204 mu A mM(-1) cm(-2), and the limit of detection is 1.3 and 0.078 mu M respectively. Furthermore, interference tests indicated that the carbon composite film exhibited high selectivity toward H2O2 and NADH. Using GO as a solubilizing agent for SWCNTs establishes a new class of carbon electrodes for electrochemical sensors. (C) 2012 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectSingle-walled carbon nanotubesen_US
dc.subjectGraphene oxideen_US
dc.subjectSensorsen_US
dc.subjectHydrogen peroxideen_US
dc.subjectB-Nicotinamide adenine dinucleotideen_US
dc.titlerGO/SWCNT composites as novel electrode materials for electrochemical biosensingen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.bios.2012.10.047en_US
dc.identifier.journalBIOSENSORS & BIOELECTRONICSen_US
dc.citation.volume43en_US
dc.citation.issueen_US
dc.citation.spage173en_US
dc.citation.epage179en_US
dc.contributor.department光電工程學系zh_TW
dc.contributor.departmentDepartment of Photonicsen_US
dc.identifier.wosnumberWOS:000316525300030-
dc.citation.woscount19-
Appears in Collections:Articles


Files in This Item:

  1. 000316525300030.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.