完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHu, Jie-Bien_US
dc.contributor.authorChen, Yu-Chieen_US
dc.contributor.authorUrban, Pawel L.en_US
dc.date.accessioned2014-12-08T15:29:48Z-
dc.date.available2014-12-08T15:29:48Z-
dc.date.issued2013-03-05en_US
dc.identifier.issn0003-2670en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.aca.2012.12.044en_US
dc.identifier.urihttp://hdl.handle.net/11536/21391-
dc.description.abstractThis report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of "coffee rings" in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the "coffee-ring effect" in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a "hidden coffee-ring effect" where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation. (C) 2013 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectCoffee-ring effecten_US
dc.subjectMatrix-assisted laser desorption/ionizationen_US
dc.subjectMass spectrometryen_US
dc.subjectSurface-assisted laser desorption/ionization sample preparationen_US
dc.subjectlaser desorption/ionizationen_US
dc.titleCoffee-ring effects in laser desorption/ionization mass spectrometryen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.aca.2012.12.044en_US
dc.identifier.journalANALYTICA CHIMICA ACTAen_US
dc.citation.volume766en_US
dc.citation.issueen_US
dc.citation.spage77en_US
dc.citation.epage82en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.identifier.wosnumberWOS:000315834100008-
dc.citation.woscount1-
顯示於類別:期刊論文


文件中的檔案:

  1. 000315834100008.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。