dc.description.abstractThe influence of particle morphology on the accuracy of nanoparticle size distributions measured by the engine exhaust particle sizer spectrometer (EEPS, TSI Model 3090) was studied using the scanning mobility particle sizer (SMPS, TSI Model 3936) as a reference. The EEPS shows higher total number concentrations with the maximum relative difference up to 67 % and smaller number median mobility diameters for polydisperse silver nanoparticles generated in the laboratory. To provide a quantitative explanation of the difference, generated polydisperse nanoparticles were classified as monodisperse particles with the initial equivalent mobility diameter (d (m1)) and sintered in the second furnace at different temperatures (room temperature to 600 A degrees C), to change their morphologies for the comparison tests. Without sintering (room temperature), results show that the measured mobility diameter (d (m2)) of the EEPS is smaller than that measured by the SMPS when d (m1) is larger than 30 nm and the difference increases as d (m1) is increased from 30 to 300 nm. But the difference decreases as the morphology of particles is changed from branched chain agglomerates to spheres for d (m1) less than 80 nm and the sintering temperature higher than 200 A degrees C. Theoretical analysis shows that the mean charge per agglomerates is more than that of spheres resulting in overestimation of the electrical mobility and underestimation of the d (m2) by the EEPS.en_US
dc.language.isoen_USen_US
dc.subjectAerosol measurementen_US
dc.subjectParticle sizeren_US
dc.subjectElectrical mobility analyzeren_US
dc.subjectSizing accuracyen_US
dc.titleThe Effect of Nanoparticle Morphology on the Measurement Accuracy of Mobility Particle Sizersen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s12647-013-0068-7en_US
dc.identifier.journalMAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIAen_US
dc.citation.volume28en_US
dc.citation.issue3en_US
dc.citation.spage205en_US
dc.citation.epage215en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000325897600007-
dc.citation.woscount4-
Appears in Collections:Articles


Files in This Item:

  1. 000325897600007.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.