標題: Pretension Effects of the Dynesys Cord on the Tissue Responses and Screw-Spacer Behaviors of the Lumbosacral Construct With Hybrid Fixation
作者: Chien, Chen-Ying
Tan, Ching-Hong
Lu, Tsai-Hsiung
Lin, Shang-Chih
Chuang, Wen-Hsien
Chiang, Ming-Chieh
Luh, Yuan-Ping
Chen, Yeung-Jen
機械工程學系
Department of Mechanical Engineering
關鍵字: junctional problem;hybrid fixation;disc degeneration;Dynesys system;finite-element
公開日期: 1-六月-2013
摘要: Study Design. The pretension of the Dynesys cord was varied to evaluate its effects on both tissue responses and screw-spacer behaviors by the finite-element method. Objective. This study aimed to provide detailed information about the motion-preserving and load-shielding mechanisms of the Dynesys screw-spacer joint. Summary of Background Data. Intuitively, higher cord pretension aims to ensure the occurrence of screw-spacer contact, thus making the spacer the transmitter of the vertebral loads. However, detailed investigations of the cord-pretension effects have not yet been carried out. Methods. Using a validated lumbosacral model, the moderately degenerative L4-L5 segment was instrumented by a static fixator and the Dynesys fixator was further used to bridge a mildly degenerative L3-L4 segment. The pre-tended cord was modeled as an elastic spring with 0- and 300-N pretensions. The disc range-of-motion, disc stress, facet force, bone-screw stress, and screw-spacer force were chosen as comparison indices. Results. At the transition and adjacent segments, the range-ofmotion differences between the 2 pretensions were 7.7% and 2.0% on average, respectively. The mechanical differences at the transition and adjacent segments were 9.0% and 5.2% (disc stress) and 9.4% and 9.1% (facet force), respectively. The results indicated that the cord pretension has a minor effect on the adjacent segments in comparison with the transition segment. However, the stress at the screw hub and force of the screw-spacer contact of the 300-N pretension were increased by 33.7% and 316.5% on average than without pretension, respectively. Conclusion. The moment arm from the screw-cord center to the fulcrum is signifi cantly less than that of vertebral loads. This leads to the minor effect of increasing the cord pretension on the responses of the adjacent segments. However, the cord pretension can signifi cantly affect both screw-spacer force and bone-screw stress.
URI: http://dx.doi.org/10.1097/BRS.0b013e318290fb2e
http://hdl.handle.net/11536/23562
ISSN: 0362-2436
DOI: 10.1097/BRS.0b013e318290fb2e
期刊: SPINE
Volume: 38
Issue: 13
起始頁: E775
結束頁: E782