完整後設資料紀錄
DC 欄位語言
dc.contributor.authorZhou, Yueen_US
dc.contributor.authorIrshad, Hammaden_US
dc.contributor.authorTsai, Chuen-Jinnen_US
dc.contributor.authorHung, Shao-Mingen_US
dc.contributor.authorCheng, Yung-Sungen_US
dc.date.accessioned2014-12-08T15:35:04Z-
dc.date.available2014-12-08T15:35:04Z-
dc.date.issued2014-02-01en_US
dc.identifier.issn2050-7887en_US
dc.identifier.urihttp://dx.doi.org/10.1039/c3em00497jen_US
dc.identifier.urihttp://hdl.handle.net/11536/23807-
dc.description.abstractThis work investigated the performance in terms of collection efficiency and aspiration efficiency of a personal sampler capable of collecting ultrafine particles (nanoparticles) in the occupational environment. This sampler consists of a cyclone for respirable particle classification, micro-orifice impactor stages with an acceleration nozzle to achieve nanoparticle classification and a backup filter to collect nanoparticles. Collection efficiencies of the cyclone and impactor stages were determined using monodisperse polystyrene latex and silver particles, respectively. Calibration of the cyclone and impactor stages showed 50% cut-off diameters of 3.95 mu m and 94.7 nm meeting the design requirements. Aspiration efficiencies of the sampler were tested in a wind tunnel with wind speeds of 0.5, 1.0, and 1.5 m s(-1). The test samplers were mounted on a full size mannequin with three orientations toward the wind direction (0 degrees, 90 degrees, and 180 degrees). Monodisperse oleic acid aerosols tagged with sodium fluorescein in the size range of 2 to 10 mu m were used in the test. For particles smaller than 2 mu m, the fluorescent polystyrene latex particles were generated by using nebulizers. For comparison of the aspiration efficiency, a NIOSH two-stage personal bioaerosol sampler was also tested. Results showed that the orientation-averaged aspiration efficiency for both samplers was close to the inhalable fraction curve. However, the direction of wind strongly affected the aspiration efficiency. The results also showed that the aspiration efficiency was not affected by the ratio of free-stream velocity to the velocity through the sampler orifice. Our evaluation showed that the current design of the personal sampler met the designed criteria for collecting nanoparticles <= 100 nm in occupational environments.en_US
dc.language.isoen_USen_US
dc.titleEvaluation of a novel personal nanoparticle sampleren_US
dc.typeArticleen_US
dc.identifier.doi10.1039/c3em00497jen_US
dc.identifier.journalENVIRONMENTAL SCIENCE-PROCESSES & IMPACTSen_US
dc.citation.volume16en_US
dc.citation.issue2en_US
dc.citation.spage203en_US
dc.citation.epage210en_US
dc.contributor.department交大名義發表zh_TW
dc.contributor.departmentNational Chiao Tung Universityen_US
dc.identifier.wosnumberWOS:000331504100003-
dc.citation.woscount0-
顯示於類別:期刊論文


文件中的檔案:

  1. 000331504100003.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。