完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Hung, Hao-Chih | en_US |
dc.contributor.author | Chang, Yung-Yu | en_US |
dc.contributor.author | Luo, Liyang | en_US |
dc.contributor.author | Hung, Chen-Hsiung | en_US |
dc.contributor.author | Diau, Eric Wei-Guang | en_US |
dc.contributor.author | Chung, Wen-Sheng | en_US |
dc.date.accessioned | 2014-12-08T15:35:38Z | - |
dc.date.available | 2014-12-08T15:35:38Z | - |
dc.date.issued | 2014 | en_US |
dc.identifier.issn | 1474-905X | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/24059 | - |
dc.identifier.uri | http://dx.doi.org/10.1039/c3pp50175b | en_US |
dc.description.abstract | 25,27-Bis{1'-N-(1-pyrenyl)-aminocarbonylmethyl-1H-[1',2',3']tri-azolyl-4'-methoxy}-26,28-dihydroxycalix-[4]arene, 4, is synthesized as a fluorescent chemosensor for the selective detection of both anions and ion pairs in MeCN. Sensor 4 uses bis-triazoles as ligands to bind a metal ion, bis-amides and bis-triazoles as the sites to recognize anions, and pyrenes as fluorophores. Among eight anions screened, chemosensor 4 showed a marked fluorescence change toward F-, H2PO4- and AcO-, but 4 responded to each anion in a distinct way. In the presence of F- at low concentrations, the dynamic excimer emission of compound 4 at lambda(max) 482 nm was quenched, but an emission at lambda(max) 472 nm appeared at large doses of F-. A control compound 6 showed very similar red shifts in the UV-vis and excitation spectra as 4 did, and its 472 nm emission band grew as the fluoride doses increased. Thus, the growth of the 472 nm emission of 4 and 6 in the presence of excess F- may be because strong H-bonding interactions of amido protons with F- favoured the formation of pyrene dimers in the ground state with charge transfer characteristics. The addition of H2PO4-, unlike F-, to a solution of 4 showed an enhanced monomer emission but a decreased excimer emission (lambda(max) 482 nm). Adding AcO- to 4 produced a systematic change from a dynamic excimer (lambda(max) 482 nm) to lambda(max) 472 nm but with very little change in the UV-vis spectrum. Time-resolved fluorescence measurements on compound 6 with F- and AcO- confirmed that the 472 nm emission band mainly came from static excimers for the former, but was partly from a dynamic excimer for the latter because it contained a growth component in the fluorescence decay traces. Without pre-treatment with an anion, chemosensor 4 showed recognition of only metal ions Cu2+, Hg2+ and Cr3+, but it became sensitive to Ag+ when it was pretreated with fluoride. | en_US |
dc.language.iso | en_US | en_US |
dc.title | Different sensing modes of fluoride and acetate based on a calix[4]arene with 25,27-bistriazolylmethylpyrenylacetamides | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1039/c3pp50175b | en_US |
dc.identifier.journal | PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES | en_US |
dc.citation.volume | 13 | en_US |
dc.citation.issue | 2 | en_US |
dc.citation.spage | 370 | en_US |
dc.citation.epage | 379 | en_US |
dc.contributor.department | 應用化學系 | zh_TW |
dc.contributor.department | Department of Applied Chemistry | en_US |
dc.identifier.wosnumber | WOS:000333091800030 | - |
dc.citation.woscount | 5 | - |
顯示於類別: | 期刊論文 |