Full metadata record
DC FieldValueLanguage
dc.contributor.authorTseng, Chih-Yungen_US
dc.contributor.authorYang, Kai-Shingen_US
dc.contributor.authorChien, Kuo-Hsiangen_US
dc.contributor.authorJeng, Ming-Shanen_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2014-12-08T15:35:54Z-
dc.date.available2014-12-08T15:35:54Z-
dc.date.issued2014-04-01en_US
dc.identifier.issn0894-1777en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.expthermflusci.2014.01.019en_US
dc.identifier.urihttp://hdl.handle.net/11536/24273-
dc.description.abstractThe present study examines the performance of closed-loop pulsating heat pipes (CLPHPs) with an ID of 2.4 mm. The effect of uniform and alternating tube diameter on the performance is investigated. The working fluids include distilled water, methanol and HFE-7100. Tests are performed with both horizontal and vertical arrangement. For the horizontal arrangement, when compared to uniform design, the alternating channel design can be started at a rather low heat input with a much smaller thermal resistance. Normally the thermal resistance is decreased with the rise of heat input, and reveals a minimum value at a certain heat input followed by shows a marginal rise when the heat input is increased further. Both uniform and alternating design reveals the similar trend. For the vertical arrangement, the thermal resistance is much lower than that in horizontal arrangement. Different from that in horizontal arrangement, the thermal resistance shows a continuous decline against heat input for all the working fluids. For a low input power, CLPHP with HFE-7100 shows the least thermal resistance. By contrast, CLPHP with distilled water shows the smallest thermal resistance when the input power is increased over 60 W. (C) 2014 Elsevier Inc. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectPulsating heat pipeen_US
dc.subjectHorizontal arrangementen_US
dc.subjectAlternating diameteren_US
dc.titleInvestigation of the performance of pulsating heat pipe subject to uniform/alternating tube diametersen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.expthermflusci.2014.01.019en_US
dc.identifier.journalEXPERIMENTAL THERMAL AND FLUID SCIENCEen_US
dc.citation.volume54en_US
dc.citation.issueen_US
dc.citation.spage85en_US
dc.citation.epage92en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000333785100009-
dc.citation.woscount1-
Appears in Collections:Articles


Files in This Item:

  1. 000333785100009.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.