dc.contributor.authorYang, Kai-Shingen_US
dc.contributor.authorLin, Chen-Chuanen_US
dc.contributor.authorShyu, Jin-Cherngen_US
dc.contributor.authorTseng, Chih-Yungen_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2014-12-08T15:36:40Z-
dc.date.available2014-12-08T15:36:40Z-
dc.date.issued2014-10-01en_US
dc.identifier.issn0017-9310en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.ijheatmasstransfer.2014.06.056en_US
dc.identifier.urihttp://hdl.handle.net/11536/25024-
dc.description.abstractIn this study, thermal performance and flow visualization of a double layer flat micro vapor chamber are reported. Two micro vapor chambers having pin fin and pin fin array support structure are fabricated and tested. The micro vapor chambers are composed of silicon and glass wafers having an overall size of 35 x 40 x 1.525 mm. Test results show that both the pin fin and pin fin array vapor chambers show an appreciably lower thermal resistance as compared to the solid silicon counterpart, the thermal resistance of the pin fin vapor chamber is about 52-60% of the solid silicon whereas the corresponding thermal resistance of pin fin array is only 17-20% of the solid silicon. The thermal resistance of the pin fin vapor chamber is moderately increased subject to the increase of supplied power whereas opposite trend is encountered for the pin fin array. The phenomenon is associated with the influence of dry-out phenomenon. It is found that the pin fin array vapor chamber is still in function even for an upside-down arrangement. The thermal resistance, however, is reduced with the rise of tilt angle, and the vertical arrangement gives the lowest thermal resistance. However, the thermal resistance is considerably increased if the heat source is placed upwards, and the corresponding thermal resistance for an upside-down heat source can be threefold higher than that of the vertical arrangement. (C) 2014 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectHeat pipeen_US
dc.subjectVapor chamberen_US
dc.subjectTwo-phase flowen_US
dc.subjectThermal resistanceen_US
dc.titlePerformance and two-phase flow pattern for micro flat heat pipesen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.ijheatmasstransfer.2014.06.056en_US
dc.identifier.journalINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFERen_US
dc.citation.volume77en_US
dc.citation.issueen_US
dc.citation.spage1115en_US
dc.citation.epage1123en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000340302400102-
dc.citation.woscount0-
顯示於類別:期刊論文


文件中的檔案:

  1. 000340302400102.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。