摘要: | Copper (Cu) contamination at the wafer bevel, back side surface, and exclusion zone is identified step-by-step following a typical dual-damascene process. The shield ring of a physical vapor deposition system does not protect the exclusion zone and bevel efficiently. Also, Cu may dissolve and accumulate in the solvent used for post dielectric etch clean. Dissolved Cu atoms may then redeposit on the wafer surface. Furthermore, the rough back side surface traps Cu atoms easier than the smooth front side surface. If there is no SiO2 film on the back side surface, post chemical mechanical polish cleaning using dilute HF cannot remove Cu at the back side surface. An optimized single-wafer spin-etch process was proposed. An optimal etchant consisting of HF, HNO3, H2SO4, and H3PO4 with ratios 0.5 :3 :1 :0.5 showed excellent performance. Experiments demonstrated that a very short, 10 s, back side clean can totally remove Cu from back side surface, bevel, and 2 mm exclusion zone. A "wafer shift" procedure was also proposed to solve the pinmark issue near the edge pin due to etchant remnant. The optimized cleaning technique shows shorter process time and higher cleaning efficiency than those reported previously. (C) 2005 The Electrochemical Society. |
URI: | http://hdl.handle.net/11536/25526 http://dx.doi.org/10.1149/1.1850381 |
ISSN: | 0013-4651 |
DOI: | 10.1149/1.1850381 |
期刊: | JOURNAL OF THE ELECTROCHEMICAL SOCIETY |
Volume: | 152 |
Issue: | 2 |
起始頁: | G131 |
結束頁: | G137 |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.