標題: One-dimensional simulation of nitrogen dielectric barrier discharge driven by a quasi-pulsed power source and its comparison with experiments
作者: Cheng, K-W
Hung, C-T
Chiang, M-H
Hwang, F-N
Wu, J-S
機械工程學系
Department of Mechanical Engineering
關鍵字: Parallel-plate;Nitrogen dielectric barrier discharge;Townsend-like;Filamentary-like;Fluid modeling
公開日期: 1-Jan-2011
摘要: Parallel-plate nitrogen dielectric barrier discharge (DBD) driven by a quasi-pulsed power source (60 kHz) is simulated using a fully-implicit 1D self-consistent fluid modeling code Simulated discharged currents of gap distances (0 5 07 and 1 0 mm) agree very well with measured data while simulated discharged currents of wider gap distance (1 2 mm) fail to reproduce the measured data It is found that the discharge mode is homogeneous Townsend-like for the former case while it is filamentary-like for the latter case based on the experimental observation These findings demonstrate that previous numerical studies showing mode transition by changing the gap distance may require further investigation (C) 2010 Elsevier B V All rights reserved
URI: http://dx.doi.org/10.1016/j.cpc.2010.06.028
http://hdl.handle.net/11536/26171
ISSN: 0010-4655
DOI: 10.1016/j.cpc.2010.06.028
期刊: COMPUTER PHYSICS COMMUNICATIONS
Volume: 182
Issue: 1
起始頁: 164
結束頁: 166
Appears in Collections:Articles


Files in This Item:

  1. 000285119900052.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.