完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Cheng, Yu-Hsiang | en_US |
dc.contributor.author | Huang, Cheng-Hsiung | en_US |
dc.contributor.author | Huang, Hsiao-Lin | en_US |
dc.contributor.author | Tsai, Chuen-Jinn | en_US |
dc.date.accessioned | 2014-12-08T15:38:16Z | - |
dc.date.available | 2014-12-08T15:38:16Z | - |
dc.date.issued | 2010-12-15 | en_US |
dc.identifier.issn | 0048-9697 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.scitotenv.2010.10.023 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/26218 | - |
dc.description.abstract | Research regarding the magnitude of ultrafine particle levels at highway toll stations is limited. This study measured ambient concentrations of ultrafine particles at a highway toll station from October 30 to November 1 and November 5 to November 6, 2008. A scanning mobility particle sizer was used to measure ultrafine particle concentrations at a ticket/cash tollbooth. Levels of hourly average ultrafine particles at the tollbooth were about 3-6 times higher than those in urban backgrounds, indicating that a considerable amount of ultrafine particles are exhausted from passing vehicles. A bi-modal size distribution pattern with a dominant mode at about <6 nm and a minor mode at about 40 nm was observed at the tollbooth. The high amounts of nanoparticles in this study can be attributed to gas-to-particle reactions in fresh fumes emitted directly from vehicles. The influences of traffic volume, wind speed, and relative humidity on ultrafine particle concentrations were also determined. High ambient concentrations of ultrafine particles existed under low wind speed, low relative humidity, and high traffic volume. Although different factors account for high ambient concentrations of ultrafine particles at the tollbooth, measurements indicate that toll collectors who work close to traffic emission sources have a high exposure risk. (C) 2010 Elsevier ay. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Ultrafine particle | en_US |
dc.subject | Number concentration | en_US |
dc.subject | Highway toll station | en_US |
dc.title | Concentrations of ultrafine particles at a highway toll collection booth and exposure implications for toll collectors | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.scitotenv.2010.10.023 | en_US |
dc.identifier.journal | SCIENCE OF THE TOTAL ENVIRONMENT | en_US |
dc.citation.volume | 409 | en_US |
dc.citation.issue | 2 | en_US |
dc.citation.spage | 364 | en_US |
dc.citation.epage | 369 | en_US |
dc.contributor.department | 環境工程研究所 | zh_TW |
dc.contributor.department | Institute of Environmental Engineering | en_US |
dc.identifier.wosnumber | WOS:000286294300015 | - |
dc.citation.woscount | 9 | - |
顯示於類別: | 期刊論文 |