標題: Control of particle re-entrainment by wetting the exposed surface of dust samples
作者: Tsai, CJ
Lee, CI
Lin, JS
Huang, CH
環境工程研究所
Institute of Environmental Engineering
公開日期: 1-Oct-2003
摘要: Experiments have been conducted in a Wind tunnel to measure the emission factor of re-entrained particles from a dry or wetted dust sample with a smooth or rough surface. Effects of wind velocities and water contents in the sample on the emission factor also were investigated. The results show that re-entrainment of particles can be controlled efficiently in a certain period of time when the surface watering density is between 60 and 80 g/m(2) at a wind velocity from 7 to 15 m/sec for both smooth and rough surfaces. After the effective period is elapsed, which depends on wind speeds and environmental conditions, water will eventually evaporate, and re-entrainment starts to occur again. The experimental water evaporation rates at different wind speeds are in good agreement with theoretical values. After watering for 210, 130, and 110 min at average wind velocities of 0, 2, and 4 m/sec, respectively, the dust sample must be replenished with water to avoid dust re-entrainment.
URI: http://hdl.handle.net/11536/27470
ISSN: 1047-3289
期刊: JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION
Volume: 53
Issue: 10
起始頁: 1191
結束頁: 1195
Appears in Collections:Articles


Files in This Item:

  1. 000185765500004.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.