完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLiu, WCen_US
dc.contributor.authorLu, MHen_US
dc.date.accessioned2014-12-08T15:41:00Z-
dc.date.available2014-12-08T15:41:00Z-
dc.date.issued2003-05-01en_US
dc.identifier.issn0020-7217en_US
dc.identifier.urihttp://dx.doi.org/10.1080/00207210310001604805en_US
dc.identifier.urihttp://hdl.handle.net/11536/27934-
dc.description.abstractA new method for locating the break point of a cable has been developed. It operates by application of the principle of the transmission line oscillator. Coaxial cables of four different lengths (1.5 m, 5 m, 10 m, 20 m) were measured in accordance with this method. The results show high precision (deviation <0.5 cm) and accuracy (error &LE;3 cm).en_US
dc.language.isoen_USen_US
dc.titleLocating faults on cables by applying the principle of the transmission line oscillatoren_US
dc.typeArticleen_US
dc.identifier.doi10.1080/00207210310001604805en_US
dc.identifier.journalINTERNATIONAL JOURNAL OF ELECTRONICSen_US
dc.citation.volume90en_US
dc.citation.issue5en_US
dc.citation.spage355en_US
dc.citation.epage359en_US
dc.contributor.department光電工程學系zh_TW
dc.contributor.departmentDepartment of Photonicsen_US
dc.identifier.wosnumberWOS:000185721100005-
dc.citation.woscount0-