標題: Characteristics of RO foulants in a brackish water desalination plant
作者: Yang, Hui Ling
Huang, Chihpin
Pan, Jill R.
環境工程研究所
Institute of Environmental Engineering
關鍵字: brackish water;scaling;fouling;membrane autopsy;foulants identification
公開日期: 1-三月-2008
摘要: This study identified the membrane fouling of a two-stage RO process of the Bai-sha brackish water desalination plant facing serious fouling problems. Two membrane modules, one from each stage, were autopsied and diagnosed for the cause for the failure of the RO system. Different morphologies were exhibited on the fouled membrane. Results suggested that the fouling on the first-stage membrane tended to be organic and biological, while that on the second-stage membrane appeared to be scaling. Higher than 85% of the foulants on the first stage membrane were organic substances in opposed to the 5 to 8% of those on the second stage membrane. However, the total organic matter on the second stage membrane was more than that on the first stage one. The thick layer of sealants on the surface of the second-stage membrane was identified to be calcium carbonate of which the crystal was clearly seen in the SEM images. The scaling was thickest at the outlet of the membrane. Huge amount of microbes were found on both membranes. The FTIR results also suggested the existence of extracellular polymeric substance (EPS) on the first stage membrane. This study recommended that the recovery rate, pH and the potential for bio-fouling should be defined at the real operation.
URI: http://dx.doi.org/10.1016/j.desal.2007.01.040
http://hdl.handle.net/11536/30087
ISSN: 0011-9164
DOI: 10.1016/j.desal.2007.01.040
期刊: DESALINATION
Volume: 220
Issue: 1-3
起始頁: 353
結束頁: 358
顯示於類別:會議論文


文件中的檔案:

  1. 000254024800034.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。