標題: | Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus |
作者: | Tseng, Yuhwai Su, Chauchin Liu, Chien-Nan Jimmy 電控工程研究所 Institute of Electrical and Control Engineering |
關鍵字: | square waveform;deconvolution;intra-body communication |
公開日期: | 1-Mar-2010 |
摘要: | This study employs a simple measurement methodology that is based on the de-convolution of a square test stimulus to measure the transmission characteristics of the human body channel in an electrostatic-coupling intra body communication system. A battery-powered square waveform generator was developed to mimic the electrostatic-coupling intra body communication system operating in the environment of the ground free. The measurement results are then confirmed using a reliable measuring method (single tone) and spectral analysis. The results demonstrate that the proposed measurement approach is valid for up to 32.5 MHz, providing a data rate of over 16 Mbps. |
URI: | http://dx.doi.org/10.1587/transfun.E93.A.664 http://hdl.handle.net/11536/5798 |
ISSN: | 0916-8508 |
DOI: | 10.1587/transfun.E93.A.664 |
期刊: | IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES |
Volume: | E93A |
Issue: | 3 |
起始頁: | 664 |
結束頁: | 668 |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.