完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHuang, Chihpinen_US
dc.contributor.authorLin, Jr-Linen_US
dc.contributor.authorWu, C. L.en_US
dc.contributor.authorChu, C. P.en_US
dc.date.accessioned2014-12-08T15:07:38Z-
dc.date.available2014-12-08T15:07:38Z-
dc.date.issued2010en_US
dc.identifier.issn0273-1223en_US
dc.identifier.urihttp://hdl.handle.net/11536/6002-
dc.identifier.urihttp://dx.doi.org/10.2166/wst.2010.146en_US
dc.description.abstractMembrane separation technology has been widely used for recycling of spent filter backwash water (SFBW) in water treatment plant. Membrane filtration performance is subject to characteristics of the particles in the SFBW. A bench-scale microfiltration (MF) coupled with pre-coagulation was set up to evaluate the recovery efficiency of SFBW. Effect of particle size distribution and zeta potential of the coagulated SFBW on the membrane filtration as well as the coagulation strategies were investigated. Pore clogging was more severe on the membrane with 1.0 mu m pore size than on the membrane with 0.5 mu m pore size due to the fact that submicrometre particles are dominant and their diameters are exactly closed to the pore size of the MF membrane. Pre-settling induced more severe irreversible fouling because only the submicrometre particles in the water become predominant after settling, resulting in the occurrence of more acute pore blocking of membrane. By contrast, pre-coagulation mitigates membrane fouling and improves membrane flux via enlarging particle size on membrane surface. The variations of zeta potential in response to coagulant dosing as well as fractal dimension were also compared with the performance of the subsequent filtration. The result showed that pre-coagulation induced by charge neutralization at the optimum dosage where the zeta potential is around zero leads to the optimal performance of the subsequent membrane filtration for SFBW recycling. At such condition, the fractal dimension of coagulated flocs reached minimum.en_US
dc.language.isoen_USen_US
dc.subjectcoagulationen_US
dc.subjectmembrane filtrationen_US
dc.subjectMFen_US
dc.subjectspent filter backwash wateren_US
dc.titleRecycling of spent filter backwash water using coagulation-assisted membrane filtration: effects of submicrometre particles on membrane fluxen_US
dc.typeArticleen_US
dc.identifier.doi10.2166/wst.2010.146en_US
dc.identifier.journalWATER SCIENCE AND TECHNOLOGYen_US
dc.citation.volume61en_US
dc.citation.issue8en_US
dc.citation.spage1923en_US
dc.citation.epage1929en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000276973400002-
dc.citation.woscount4-
顯示於類別:期刊論文