標題: | Measurements of respirable dust and nanoparticle concentrations in a titanium dioxide pigment production factory |
作者: | Huang, Cheng-Hsiung Tai, Chih-Yuan Huang, Cheng-Yu Tsai, Chuen-Jinn Chen, Chun-Wan Chang, Cheng-Ping Shih, Tung-Sheng 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | Respirable dust;nanoparticles;particle concentration;titanium dioxide |
公開日期: | 2010 |
摘要: | This study compared respirable dust and nanoparticle concentrations measured by different sampling devices at a titanium dioxide pigment factory. Respirable particle mass concentrations, nanoparticle concentrations, particle size distribution and particle metallic content were measured at different sampling locations. The sampling results of the Multi-orifice Uniform Deposit Impactor (MOUDI) showed that the particle size distribution at this titanium dioxide production factory fell in the range of 1-10 mu m. Generally, the higher levels of the respirable particle mass concentrations and nanoparticle number concentrations were near the packing site of the pigment titanium dioxide production factory. Metal analysis results revealed that the titanium dioxide concentrations in respirable dust and nanoparticles were within the limits specified by National Institute for Occupational Safety and Health (NIOSH). During sampling, particle metallic content analysis is essential for identifying the source of particles and for measuring respirable dust and nanoparticle concentrations. |
URI: | http://hdl.handle.net/11536/6075 http://dx.doi.org/10.1080/10934529.2010.493792 |
ISSN: | 1093-4529 |
DOI: | 10.1080/10934529.2010.493792 |
期刊: | JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING |
Volume: | 45 |
Issue: | 10 |
起始頁: | 1227 |
結束頁: | 1233 |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.