完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLin, Guan-Yuen_US
dc.contributor.authorTsai, Chuen-Jinnen_US
dc.date.accessioned2014-12-08T15:07:44Z-
dc.date.available2014-12-08T15:07:44Z-
dc.date.issued2010en_US
dc.identifier.issn0278-6826en_US
dc.identifier.urihttp://hdl.handle.net/11536/6083-
dc.identifier.urihttp://dx.doi.org/10.1080/02786826.2010.512320en_US
dc.description.abstractThe numerical models for predicting the collection efficiency of particles in the size range of 0.3 similar to 10.0 mu m in electrostatic precipitators (ESPs) have been well developed. However, for nanoparticles, or particles with the diameter below 100 nm, the existing models can't predict the collection efficiency very well because the electric field and ion concentration distribution were not simulated, or charging models were not adopted appropriately to calculate particle charges. In this study, a 2-D numerical model was developed to predict the nanoparticle collection efficiency in single-stage wire-in-plate ESPs. Laminar flow field was solved by using the Semi-Implicit Method for Pressure-Linked Equation (SIMPLER Method), while electric field strength and ion concentration distribution were solved based on Poisson and diffusion-convection equations, respectively. The charged particle concentration distribution and the particle collection efficiency were then calculated based on the convection-diffusion equation with particle charging calculated by Fuchs diffusion charging theory. The simulated collection efficiencies of 6-100 nm nanoparticles were compared with the experimental data of Huang and Chen (2002) for a wire-in-plate dry ESP (aerosol flow rate: 100 L/min, applied voltage: -15.5 similar to -21.5 kV). Good agreement was obtained. The simulated particle collection efficiencies were further shown to agree with the experimental data obtained in the study for a wire-in-plate wet ESP (Lin et al. 2010) (aerosol flow rate: 5 L/min, applied voltage: +3.6 similar to +4.3 kV) using monodisperse NaCl particles of 10 and 50 nm in diameter. It is expected that the present model can be used to facilitate the design of ESPs for nanoparticle control and electrostatic nanoparticle samplers.en_US
dc.language.isoen_USen_US
dc.titleNumerical Modeling of Nanoparticle Collection Efficiency of Single-Stage Wire-in-Plate Electrostatic Precipitatorsen_US
dc.typeArticleen_US
dc.identifier.doi10.1080/02786826.2010.512320en_US
dc.identifier.journalAEROSOL SCIENCE AND TECHNOLOGYen_US
dc.citation.volume44en_US
dc.citation.issue12en_US
dc.citation.spage1122en_US
dc.citation.epage1130en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000285542000001-
dc.citation.woscount11-
顯示於類別:期刊論文


文件中的檔案:

  1. 000285542000001.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。